• If a secure alternative is available for a protocol, use it.
The following protocols provide secure alternatives:
– SNMPv1/v2 → SNMPv3
– HTTP → HTTPS
– Telnet → SSH
– NTP → Secure NTP
– TFTP → SFTP
– TIA Portal Cloud Connector using a secure connection. Use the "TIA Portal Cloud
• Using a firewall, restrict the services and protocols available to the outside to a minimum.
• For the DCP function, enable the "Read Only" mode after commissioning.
2.2

Available services

List of available services
The following is a list of all available protocols and services as well as their ports through which
the device can be accessed.
The table includes the following columns:
• Service
The services that the device supports.
• Protocol / Port number
Port number assigned to the protocol.
• Default port status
The port status on delivery (factory setting) distinguishes between local and external access.
– Local access: The port is accessed via a local connection (vlan1).
– External access: The port is accessed via an external connection (vlan2).
• Configurable port/service
Indicates whether the port number or the service can be configured via WBM / CLI.
• Authentication
Specifies whether an authentication of the communication partner takes place or whether
an authentication can be configured.
• Encryption
Specifies whether the transfer is encrypted or whether the encryption can be configured.
SCALANCE MUM856-1
Operating Instructions, 02/2023, C79000-G8976-C628-05
Check whether use of SNMPv1 is necessary. SNMPv1 is classified as non-secure. Use the
option of preventing write access. The product provides you with suitable setting options.
If SNMP is enabled, change the community names. If no unrestricted access is necessary,
restrict access with SNMP.
Connector" integrated in the product over a VPN solution (e.g. SINEMA RC).
Configure the firewall settings of the SCALANCE M800/S615 (e.g. predefined IPv4 rules
"Cloud Connector" to prevent unauthorized access of network devices to the "TIA Portal
Cloud Connector Server").