3. To release the CLP
4. Remove the CLP from the slot.
5. Close the slot cover (torque 0.8 Nm) to ensure that the device maintains the degree of
protection IP65.
Inserting the CLP
To insert a CLP into the device, follow the steps below:
1. Turn off the power to the device.
2. Loosen the screws M3
As an alternative, you can loosen only one of the screws
the side.
3. The housing of the CLP has a rounded underside (B). Accordingly, the slot opening has a
rounded edge. Note this orientation when inserting the CLP.
Insert the CLP
4. Close the slot cover (torque 0.8 Nm) to ensure that the device maintains the degree of
protection IP65.
SCALANCE MUM856-1
Operating Instructions, 02/2023, C79000-G8976-C628-05
, insert a screwdriver between the front edge of the CLP (A) and the slot.
A
in the correct orientation into the slot.
B
with a Torx screwdriver T10 and remove the slot cover
Connecting up
5.8 Replacing a CLP
and swivel the slot cover
.
to
55