UVe-LUX Operators Manual
NDT Consultants Ltd
Middlemarch House, Siskin Drive, Coventry
+44 (0)2476 511151
sales@ndt-consultants.co.uk
24/11/2009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UVe-LUX and is the answer not in the manual?

Questions and answers

Summary of Contents for NDT UVe-LUX

  • Page 1 Ver 1.02 UVe-LUX Operators Manual NDT Consultants Ltd Middlemarch House, Siskin Drive, Coventry +44 (0)2476 511151 sales@ndt-consultants.co.uk 24/11/2009...
  • Page 2 Revision History Version Date Page Description 1.00 20/11/09 1st draft 1.01 23/11/09 Typos and spelling mistakes corrected. 1.02 24/11/09 References to visible light replaced with WL (white light). Menu system section revised UVe-LUX Operators Manual ver 1_02.docx 24/11/2009...
  • Page 3: Table Of Contents

    Introduction ............................ 1 System Components ........................1 Sensor housing ........................1 Meter housing ......................... 2 Buttons ............................ 2 The Battery ..........................3 Display ............................. 4 2.5.1 Measurement Display ..................... 4 2.5.2 Menu system ........................5 UVe-LUX Operators Manual ver 1_02.docx 24/11/2009...
  • Page 4: Introduction

    1 Introduction The UVe-LUX is a compact, lightweight and robust meter specifically designed for the non- destructive testing environment. The meter is a dual white-light (WL) and ultra-violet (UV) meter designed to give simultaneous readings of both WL and UV. The meter has the following specification: ...
  • Page 5: Meter Housing

    Figure 4 Buttons 2.3 Buttons On/Off button: Pressing this button when the unit is off will switch the UVe-LUX on. Holding this button down when the system is on will switch the system off. Pressing this button while the system is in measurement mode will reset the max WL and max UV readings.
  • Page 6: The Battery

    It is recommended to replace the battery every 12 months and to remove the battery when the UVe-LUX is to be stored for a long period of time without use. When the battery indicator (see display section) is reading ‘LOW’ the battery should be replaced. The meter may not give accurate readings when the battery is low.
  • Page 7: Display

    “>5000” “>10000” or “++++” in red to indicate that it has saturated. The meter will return to normal operation once the light levels have returned to the meters design range. UVe-LUX Operators Manual ver 1_02.docx 24/11/2009...
  • Page 8: Menu System

    Holding the ON/OFF key down for several seconds in menu mode will power the system down. Brighter Brightness Darker Set auto- Back Settings menu Calibration Foot Set units menu Candles Programing Main menu Back Back menu About Power Down Figure 11 Menu Hierarchy UVe-LUX Operators Manual ver 1_02.docx 24/11/2009...
  • Page 9 Figure 15 Set Units Back – returns to Main menu. Calibration menu – not accessible to user. Programming menu – not accessible to user. About – Displays information about meter. Power Down – powers down meter. UVe-LUX Operators Manual ver 1_02.docx 24/11/2009...