TROUBLESHOOTING
PROBLEM
CAUSE
Unit is Leaking
Loose Fitting.
Oil at Fitting(s)
Rust in Water
Compressors are designed to accumu-
When Draining
late moisture in the air tank instead of in
Tank
your air stream.
Defective Pressure gauge.
Unit Will Not
Reach 145 PSI,
Defective Pressure Switch
Shuts Off Early
(On/Off switch).
Light, intermittent use, operation
Sludge in Oil
in warm, damp locations, or during
Tank and On
high humidity weather conditions will
Dipstick
contribute to the formation of excess
condensation in the system.
14
CORRECTION
Tightening fitting resolves most issues.
We recommend draining air tank weekly to remove moisture. It is not uncom-
mon to have brown/rust colored water in tank as the inside of the tank is bare
steel to eliminate any coating delamination. This will ultimately disappear as a
film of oil will coat inside of tank during use (see page 9).
Replace pressure gauge with known good gauge and retest unit. If gauge is
accurate replace Pressure Switch #32207.
Replace Pressure Switch #32207.
Drain and replace oil with 2 qts #31718 Eastwood Scroll Compressor Oil.
Replace Oil Filter #31715.
Replace Moisture Filter #31716.
See Monthly Maintenance Guide regarding Moisture Draining of oil tank.
Eastwood Technical Assistance: 800.343.9353 >> tech@eastwood.com