Eastwood 31915 Instructions Manual

Eastwood 31915 Instructions Manual

29 gallon single stage air compressor

Advertisement

Quick Links

Item #31915
29 GALLON SINGLE STAGE
AIR COMPRESSOR
INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Eastwood 31915

  • Page 1 Item #31915 29 GALLON SINGLE STAGE AIR COMPRESSOR INSTRUCTIONS...
  • Page 2: Specifications

    The Eastwood 29 Gallon Single Stage Air Compressor is specifically designed with the home garage user in mind. The twin-cylinder layout delivers higher efficiency and operates at lowered sound and vibration levels, while providing sufficient air volume to operate most home hobbyist air tools and paint guns.
  • Page 3 Pull the Pressure Relief Valve ring daily to test that the valve is functioning properly, & to clear the valve of any obstructions. REQUIRES 120 VAC, 13.8 AMP, 60Hz. This unit is equipped with a Grounded Plug. It may be hardwired, however the warranty will be void if not performed by a licensed electrician. To order parts and supplies: 800.345.1178 >> eastwood.com...
  • Page 4 Disconnect Air Line Connection The Eastwood 29 Gallon Compressor is designed with a convenient, pre-installed 3/8” Female Quick-Disconnect at the air outlet and is compatible with most 1/4” NPT, 3/8” Male Quick Disconnect fittings (Fig 3). To utilize the maximum performance from the Compressor, it is strongly recommended to use 3/8” or larger air lines and fittings throughout your system. The use of less than 3/8”...
  • Page 5: Condensation Drain

    4. Drain moisture from tank into a suitable container. Condensate is a polluting material and should be disposed of in compliance with local regulations. If drain valve becomes clogged, release all air pressure, remove and clean valve, then reinstall. To order parts and supplies: 800.345.1178 >> eastwood.com...
  • Page 6: Maintenance

    FIG. 5 As long as the SCFM capacity (5.9 scfm @ 90 psi, 7.3 scfm @ 40 psi) of the Eastwood 29 Gallon Compressor is not exceeded, it is capable of running continuous automatically controlled on/off cycles. If the SCFM demands are exceeded, the Compressor will run continuously in efforts to meet demand.
  • Page 7 5. Tap to remove any accumulation of dirt and debris then blow it out under low pressure (approx. 40 PSI [3 bar]). 6. Re-install Filter to Housing and re-attach to Cylinder Head with Screws and tighten securely (Fig 10). FIG. 11 To order parts and supplies: 800.345.1178 >> eastwood.com...
  • Page 8 1. Loosen four Motor Mount Bolts with two 13mm wrenches (NOT INCLUDED) (Fig 14). FIG. 14 2. Push Motor outward to increase belt tension, tighten bolts then re-check belt deflection. 3. Re-install Belt Guard. Tighten all fasteners securely. 2 of 4 Motor Mounts Eastwood Technical Assistance: 800.544.5118 >> techelp@eastwood.com...
  • Page 9: Troubleshooting

    Motor Overheats Dirt & debris buildup in air intake filter Follow “Cleaning Air Filter” under MAINTENANCE Supply voltage to motor too low Determine cause of under voltage condition and resolve To order parts and supplies: 800.345.1178 >> eastwood.com...
  • Page 10 Eastwood Technical Assistance: 800.544.5118 >> techelp@eastwood.com...
  • Page 11 To order parts and supplies: 800.345.1178 >> eastwood.com...
  • Page 12: Optional Items

    Eastwood Industrial Air Hose, 3/8" x 50' If you have any questions about the use of this product, please contact The Eastwood Technical Assistance Service Department: 800.544.5118 >> email: techelp@eastwood.com PDF version of this manual is available online >> eastwood.com/31915manual...