Nortel V2 Release Note page 29

Nortel v2 software: release note
Table of Contents

Advertisement

11 Lift the top latch while pushing down on the bottom latch, and begin to slide the
link select card towards you.
12 Place the link select card in an anti-static bag or box, and put aside.
13 Remove the replacement link select card from its anti-static bag or box.
14 Carefully slide the replacement link select card in the slot until the connector at
the back of the card contacts the connector on the backplane of the shelf.
15 The two latches at the top and bottom of the card should now be in the latch rail
to lock the link select card in place.
16 Actuate the latches to install the card.
17 Re-connect the HSI cable to the link select card.
18 Observe the color of the LED:
a. If the LED is now green (solid or flashing) and stays in that state, then inform
the network operator that you completed this procedure.
b. Otherwise replace the HSI cable (see "Removing and installing high-speed
interconnect (HSI) cables" on page 21).
19 Inform the network operator that you completed this procedure.
Magellan Vector 2.0 Release Notes, Issue 1.9.1