ION 30ACi Operation Manual page 5

Battery back-up system
Table of Contents

Advertisement

30ACi
Battery Back-Up System
and the pump cord into the switch cord. See
Page 5, Figure A.
8. Connect the inverter power cord to 120 AC
power and turn the MCB switch to ON position.
Your system is now ready.
9. Powering Up
To charge your battery, make sure the MCB is
in the ON position. The LCD display will come
on and show the condition of the battery. If the
battery is fully charged, the battery display will
have all bars lit and show 100%. If the battery is
charging, the battery display will cycle the bars
from bottom to top and show the percentage of
charge. This shows that the charger is working
properly in AC mode. Any AC load powered by
the inverter should also work at this point, since
a portion of the AC power is passed through the
inverter to power the load.
The Power button on the front of the inverter is
to be used in the event that the battery needs to
be replaced while the unit is in DC mode, See
Page 3, Replacing Battery. If setting up the
inverter when AC power is available, the Power
button is automatically on. If the button is held
in for 3 - 5 seconds while in AC mode, the
display will go blank and the inverter will be off.
The inverter can be turned back on by holding
in the Power button again for 3 - 5 seconds or
unplugging the inverter from the wall outlet for
10 seconds and plugging it back in.
Note: The range of the switch is the distance between
the On and Off levels. The Off level is at the bracket
mounting screw of the switch. From this point,
measure up to find the On level, see Page 5, Figure
B.
The Ion
switch does not operate like a standard
®
pressure switch. There are no contacts to wear out,
so when pressure is applied, there will not be a click.
10. Testing
While the inverter is on AC power, fill the basin
up with a bucket or garden hose to verify that
the pump turns on at the correct level. Once
the pump turns on, let it pump the basin out
until it shuts off. Repeat three times.
Unplug the power cord from the wall outlet. The
inverter will beep with the battery bars cycling
OPERATION MANUAL
Dated: 07/23/2013
Document Name: 30ACi_OM
from top to bottom. The battery percentage will
slowly start to drop. The inverter is now in DC
mode, taking the battery power and using it
to power the load uninterrupted. Fill the basin
again, as described above, to verify the pump's
operation in DC mode. Make sure you plug
the inverter back into the wall outlet.
The above steps will complete a function test of
the inverter. If all areas pass, the inverter is ready
for use. If any areas fail, see the troubleshooting
table.
FIGURE A
Ion
Switch
®
piggy back
Pump plug
FIGURE B
Range
of 6"
Register your product at www.sumpro.com
Page 5 of 12