Device Description; Device Operation - Pro AQ180G Manual

Crossline laser
Table of Contents

Advertisement

Available languages

Available languages

DEVICE DESCRIPTION

- The cross line laser generates two lines that intersect at an angle of 90°.
- Determining bevels thanks to the pendulum lock function
(the mode is signaled by the beam flashing every 3-5 seconds).
- Self-leveling thanks to the magnetic compensator.
- IP54 protection rating.
- Automatic warning with laser lines pulsing when the device exceeds the
tolerance of 3±1 degrees of the self-leveling range.
- Easy installation on 1/4" thread tripods and extension poles.

DEVICE OPERATION

Battery
To charge the device, connect the charger from the set to the USB-C socket in the battery body. The
battery can also be charged while the device is running.
The battery charge level indicator consists of 4 LEDs. When only 1 LED is blinking - the battery is very
low and needs to be recharged. During charging, successive LEDs will light up and blink in sequence to
represent the current state of charge. When all 4 LEDs are lit steadily, the battery is fully charged.
It is recommended that the first charge be longer than 6 hours. Each subsequent charge should take
more than 5 hours, but less than 24 hours. If the battery is not used for a long time, it is recommen-
ded to charge it once every 6 months. ATTENTION! Use only the original charger and battery.
Self-leveling mode
d
To turn on the device in the self-leveling mode, move the slider to the
The self-leveling range is 3°±1°. Place the device on a flat surface. If the device is within the self-leve-
ling limits, the laser lines will shine continuously. Flashing of the laser lines means that the device is
outside the self-leveling range - you need to manually adjust the device. ATTENTION! In order to finish
work, set the slider in position
Transporting the device with the pendulum unlocked may damage the device.
Manual mode for determining the bevels
To start the device in the manual mode for determining bevels (with the pendulum locked), move the
slider to the
position and press the
beams on. Manual mode is signaled by the laser line flashing every 5 seconds.
To turn off the device working in manual mode, press and hold the
or move the slider to position
8
ver. 2.1
Removable battery
.
button. By default, the device turns on with the V and H
and then to position
USB-C socket
ket
charge level
indicator
[button until the beam goes out,
.
position.