Mounting Hole Specifications

■ MTG50 Self stand base module DC/ Self stand base module AC
① Machine holes on the mounting surface referring to the diagram below.
② Remove the flange nuts from bolts and place the product through the mounting surface holes.
③ Fasten the flange nuts on the opposite side of the mounting surface until the product is tightened securely.
Installation Environment and Protection Rating
• This product is designed for indoor use with protection rating of Non-Waterproof(High-volume buzzer type)/ IP65(Waterproof
buzzer type).
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP65), it may cause malfunction or damage to the product.
• For further information, please visit our website(www.qlight.com).
• Disassembling lens kits
Twist the upper lens kit in a
counter-wise direction so the
"I" mark from both kits align.
Disassemble by removing the
upper lens kit from the lower
one.
• Assembling lens kits
① Put the two lens kits together
by aligning the upper lens' "I"
mark and the lower lens' "I"
mark together.
② Lock the two kits by twisting the
upper lens kit in a counter-wise
direction so the upper lens' " ◁ "
mark aligns with the lower lens'
"I" mark.
3-Ø5 HOLES
Ø8 HOLES
PCD 30
※ Cautions
Contact
Point
12
Lens modules are connected through
cone-shaped contact point. In case
the contact point is damaged, it may
cause a contact failure.