Terminal Box Wiring Instructions
①
Parts Definition/ Installation/ Light Function Selection
■ Parts Definition
Protection cage
(STS316L)
Lens (Tempered glass)
Housing(Al)
①
■ Installation
• First, machine taps or holes on the mounting surface ① .
• The mounting hole of this product is 8.5mm in diameter.
• When machining taps, fasten the bolt through the mounting hole of the product.
• When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface.
Mounting Hole Specifications
• Machine holes on the mounting surface referring to the
diagram below.
4-Ø9 HOLES
• Terminal block is located inside of the product. Unscrew the 4 bolts located in
the upper body to get rid of the upper lighting element of the unit.
• Please apply fork (U-type) or ring (O-type) locking spade terminal at naked tip
of the wire for secure connection.
• Please wire the power line to terminal ①
• For AC type products, wire regardless of polarity.
• For DC type products, wire terminal of black line to (-) polarity.
※ Applicable cable range : AWG16-AWG22
■ Light Function Selection(SEAL only)
• •
• Default function is set at steady LED. Select the desired function
3
Please refer to the chart below to use light function
selection switch located inside the product.
▶L : Steady
for your application during installation.
Grounding Instructions
Please use an M4 bolt at the location marked in the diagram
•
above to ground the product.
•
When connecting the grounding cable, please use a ring terminal.
• Please use a grounding cable with a diameter greater than 4mm.
▶LF : Flashing
M4 ground contact part