Steady/Flashing LED Tower Lights
STG40/ STG50
30
50
54
65
Thank you for purchasing Qlight's products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to fire, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, fire, electric shock and loss of life.)
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, and or malfunction of the
product that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product's specification.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.
Ordering Specifications
STG40/ 50(M)L
-
[Model number]
|
STG40/ 50ML
STG40/ 50ML-BZ
STG40/ 50MLF
STG40/ 50MLF-BZ
STG40/ 50L
STG40/ 50L-BZ
STG40/ 50LF
STG40/ 50LF-BZ
Please scan the QR code for more
detailed product information.
www.qlight.com
85dB
3
110/220
-
[Layer count]
[Voltage]
|
• 1 Layer
12-DC12V
• 2 Layers
24-DC24V
• 3 Layers
110/220 - AC110V~220V
• 4 Layers
• 5 Layers
RAG
-
[Color]
|
|
R-Red
A-Amber
G-Green
B-Blue
W-White
1
LW18
-
[Mounting option]
|
• (Blank)
- Standard type
• Mounting type
- LB18
- LW18
- QZ18
- SZ18
- QL18
- SL18
- QLA18

Advertisement

loading

Summary of Contents for Qlightec STG40

  • Page 1 Steady/Flashing LED Tower Lights STG40/ STG50 85dB Thank you for purchasing Qlight’s products. Please read this user manual carefully prior to installation and operation to ensure safe and correct use. Precautions for Safety Failure to follow the instructions below may cause a loss of life or serious physical injury.
  • Page 2: Product Specifications

    AC110V~220V B-Blue 0.080A 0.69kg 0.080A 0.55kg W-White W-White ※ STG series CE Compliant : DC / UL listed : DC24V • STG40 Signal/ Audible line current(Per each layer) Current AC/DC12V AC/DC24V AC110V~220V Signal line current 0.075A 0.045A Max.0.040A Audible line current 0.045A...
  • Page 3 Dimensions (Units : mm) STG40(M)L • STG40L : DC STG40L : AC STG40LF : AC STG40ML : DC STG40ML : AC STG40MLF : AC STG40LF : DC STG40LF-BZ : DC STG40L-BZ : AC STG40MLF : DC STG40MLF-BZ : DC STG40ML-BZ : AC...
  • Page 4: Wiring Instructions

    • STG □□ (M)L - Refer to this diagram for buzzer type product buzzer type product • STG □□ L • STG □□ L Lens diameter 40(40mm) : STG40(M)L Lens diameter 40(40mm) : STG40(M)L 50(50mm) : STG50(M)L 50(50mm) : STG50(M)L DC steady/flashing...
  • Page 5 Fuse Fuse Black Black • STG □□ (M)LF - Refer to this diagram for buzzer type product • STG □□ L Lens diameter 40(40mm) : STG40(M)LF 50(50mm) : STG50(M)LF DC steady/flashing AC steady/flashing PNP - Transistor External Transistor-PNP PNP - Transistor...
  • Page 6: Parts Definition

    Parts Definition Long bolt Cover(ABS) Lens(AS) Housing(ABS) Sound volume lever Pipe(Al) How to Change Lens Kit ※ Cautions Contact Point Please ensure that contact points of the two lens kits are Lens modules are connected through contact aligned together prior to assembly. Slowly combine the color point of each module.
  • Page 7: Mounting Hole Specifications

    PCD 30 ( Max. 85±4dB/m ) STG40/ 50ML ② Remove the flange nuts from bolts and place the product through the mounting surface holes. ③ Fasten the flange nuts on the opposite side of the mounting surface until the product is tightened securely.
  • Page 8 ■ STG40L/ STG50L - Pole Mounting Type Model Dimensions STG40 series Ø18 STG50 series Ø18 Ø18 Ø18 Ø18 Ø18 M18x1.5 M18x1.5 THREAD M18x1.5 THREAD THREAD 2-Ø8.5 HOLES 2-Ø8.5 HOLES 2-Ø8.5 HOLES 18mm SCREW & NUT LB18 4-Ø5 HOLES Ø18 4-Ø5 HOLES Ø18...
  • Page 9 Product installation direction ■ Install the product in accordance with the manual. Otherwise rainwater or moisture may penetrate into the product. ㆍBEACON/SIGNALING LIGHT ※ For products with a protection rating of less than IPX4, please install it vertically. Power cord inlet part shall not be facing the sky. ㆍ...
  • Page 10 MEMO...
  • Page 11 MEMO...
  • Page 12 Specification and dimensions listed in this catalogue subject to change without notice for product quality improvement. For your safety The newest product information is available on our website.(www.qlight.com) Please read the instruction manual attached to the product carefully before installation and use. Qlight Co., Ltd.