Bosch INTEGRUS User Manual page 49

Wireless language distribution system
Table of Contents

Advertisement

INTEGRUS
Figure 7.4: System with master and slave transmitter in multi purpose room
Cable length
master-slave
transmitter
[m]
50
Table 7.3: Calculation of the master-to-slave signal delays
Radiator
number
1
2
3
4
5
6
7
8
9
Bosch Security Systems B.V.
20m
R1
R2
R3
R5
20m
R4
R6
R7
20m
R8
R10
R9
20m
Cable signal
delay per meter
[ns/m]
5.6
Trans-
Master-to-
mitter
slave signal
delay [ns]
Master
0
Master
0
Master
0
Master
0
Master
0
Slave
313
Slave
313
Slave
313
Slave
313
30m
20m
Tx1
30m
50m
30m
Tx2
20m
30m
Cable signal delay
[ns]
50x5.6=280
Cable
Total signal
signal
delay [ns]
delay
[ns]
168
0+168=168
280
0+280=280
112
0+112=112
168
0+168=168
280
0+280=280
168
313+168=481
280
313+280=593
112
313+112=425
168
313+168=481
User manual
Configuration | en
Signal delay slave
Master-to-slave
transmitter [ns]
signal delay [ns]
33
280+33=313
Signal delay
Delay switch
difference
position
[ns]
593-168=425
425/33=12.88=13
593-280=313
313/33=9.48=9
593-112=481
481/33=14.58=15
593-168=425
425/33=12.88=13
593-280=313
313/33=9.48=9
593-481=112
112/33=3.39=3
593-593=0
0/33=0
593-425=168
168/33=5.09=5
593-481=112
112/33=3.39=3
49
2023-01 | V01 |

Advertisement

Table of Contents
loading

Table of Contents