Cub Cadet XR2 1000 User Manual page 24

Robotic mower
Table of Contents

Advertisement

Available languages

Available languages

Set Main Zone Area:
Scroll to select an approximate area
(EU-m
/US-ft
) for the Main Zone, where
2
2
the Base Station is installed.
If an additional zone (Sub-Zone or
Separated Zone) exists, do not include it in
main zone's area (it will be set separately).
To restart the One-Time Setup process press and hold
STOP + Settings + Left arrow together for more than 4
TIPS
seconds. This will invoke Factory Defaults
(out-of-the-box settings).
C. Test Base Station Position
After setting the area,
U001
("Test
Base Station Position") is displayed:
Place the mower on the
lawn, 3 m (10 ft) in front
of the entrance to the
Base Station, facing the
Perimeter Wire, and press
OK to start the test.
46
The mower will drive to the Base Station
and enter it.
Next, it will drive out and wait in front of
the Base Station and display U002 ("Peg
Base").
Insert the remaining two stakes into
the Base Station. Press OK.
If the E3 ("No wire signal") message is displayed, check that
the Power Supply, power cord and Base Station wires are all
connected properly. Check for possible Perimeter Wire cuts.
If the UO51 ("Reposition Base Station") message is
displayed, check that the Base Station is aligned with the
Perimeter Wire. Move any obstacles preventing entry into
the Base Station.
• Be careful not to damage irrigation pipes when
hammering down the stakes.
47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents