Set The Output Mode (Amp Mode) - Bosch PRM-4P600 Installation Manual

Hide thumbs Also See for PRM-4P600:
Table of Contents

Advertisement

Power amplifier
5.1.1

Set the output mode (AMP MODE)

100 V
70 V
8 Ω
4 Ω
100 Volt and 70 Volt modes
The use of either the 70 V or 100 V modes allow connection of high impedance (HZ)
loudspeaker lines without using output transformers. In this case the maximum number of
loudspeakers connected to an output channel is only limited by the amplifier channel output
power.
It is recommended that this mode should be used if the distance between amplifier and
speaker is larger than 50 m of cable distance (approx. 150 ft) and/or a high number of small
speakers with transformers are used.
When 100 V or 70 V is selected a 50 Hz High Pass filter is automatically activated to reduce the
possibility of loudspeaker transformer saturation to ensure the best performance.
8 Ω mode
In 8 Ω mode the power amplifier reaches rated output power having a load of 8 Ω connected.
4 Ω mode
In 4 Ω mode the power amplifier reaches the rated output power with a single cabinet rated at
4 Ω or two cabinets of 8 Ω each, or up to 4 cabinets of 16 ohms each. These configurations
can be driven by each amplifier channel. This mode usually used if multiple speakers with
medium or low‑power rating are driven in low impedance mode (LZ).
Refer to
Bosch Security Systems B.V.
AMP MODE
SPEAKER EQ
CH 1 CH 2
CH 1 CH 2
DUAL
PARALLEL CH 1/2
Indicators, controls and settings, page 16
APD
HP 1
100 V
OFF
HP 2
70 V
ON
LP
8 Ω
FLAT
4 Ω
Installation manual
Installation | en
AMP MODE
SPEAKER EQ
CH3
CH4
CH3
CH4
DUAL
PARALLEL CH 3/4
2023-01 | V02 | F.01U.402.247
17
IN1 to ALL
HP 1
OFF
HP 2
ON
LP
FLAT

Advertisement

Table of Contents
loading

Table of Contents