Power outputs 5.2.4 Ready/Fault relay 5.2.5 Remote on 5.2.6 Mains power Operation after installation Power on Input level control Troubleshooting Maintenance Technical data Approvals Circuit diagram Support and academy Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
13. To prevent hearing damage do not listen at high volume levels for long periods. 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help. Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
Notice of liability While every effort has been taken to ensure the accuracy of this document, neither Bosch Security Systems nor any of its official representatives shall have any liability to any person or entity with respect to any liability, loss or damage caused or alleged to be caused directly or indirectly by the information contained in this document.
Power amplifier About this manual | en Document history Release date Documentation version Reason 2022.02.01 Release Release date Documentation version Reason 2022.02.01 Release Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
| Product introduction Power amplifier Product introduction The PRM-4P600 is a 600 W power amplifier with powerTANK technology that flexibly delivers the total power over its 4 channels. The amplifier is ideally suited to background music and clear voice announcement applications such as: –...
Page 9
Equipped with a PFC power supply and protection features usually reserved for the professional power amplifiers, means that the amplifier resists complete shutdown situations and will always perform at its best under all conditions. Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
The products should be unpacked and handled with care. If an item appears to be damaged, notify the shipper immediately. If any items are missing, notify your Bosch representative. The original packaging is the safest container in which to transport products and can also be used to return products for service, if necessary.
This power amplifier has been designed for installation in a conventional 19”‑equipment rack. Attach the power amp with its frontal rack mount ears using four screws and washers as shown in the illustration. 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...
Page 13
When installing the power amp in a case or rack system, attention should be paid to these details to provide sufficient ventilation. Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
LEDs on the front panel and the Fault relay. However, even in such a condition the amplifier will operate without switch‑off or reduction if supervised and monitored levels are within the range of silent running parameters. 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...
= Power dissipation – (4) The following factors can be used for easy conversion of mains current: – 100 V = 2.3 – 120 V = 1.9 – 240 V = 0.96 Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
This mode usually used if multiple speakers with medium or low‑power rating are driven in low impedance mode (LZ). Refer to – Indicators, controls and settings, page 16 Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
ON or OFF using the IN1 to ALL DIP switch at the rear of the device. Level control CH1 affects the volume of all 4 output channels at the same time. Refer to – Indicators, controls and settings, page 16 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...
FLAT is designed for full range operation and contains a 30 Hz 24 dB/Oct high‑pass filter for both 4 Ω and 8 Ω operation or the 50 Hz 24 dB/Oct high pass filter when used in 70/100 V operation. Refer to – Indicators, controls and settings, page 16 Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
HF-control lines, etc., using balanced cabling and connections is always preferable. Notice! Euroblock input connectors must be inverted when inserting the connector to the device (screws downwards). Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
Page 22
Unbalanced input connection Cold Shield Jumper from cold to shield – The pin out is labeled on the rear of the amplifier. Refer to – Indicators, controls and settings, page 16 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...
Do not connect AMP‑LINK with Ethernet, CAN bus, Call station, or even PoE powered ports! Noise can occur which may damage speakers or the amplifier. Refer to – Indicators, controls and settings, page 16 Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
*) RDY/FLT: Indicates the closed contact. Figure A shows the FLT (fault) condition, figure B shows the RDY (all is ok) condition. Refer to – Indicators, controls and settings, page 16 Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
The front power button doesn't disconnect the device from mains. The only way to switch‑off mains entirely is to remove the power plug. Refer to – Technical data, page 31 – Indicators, controls and settings, page 16 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...
The level control of the unused input is ineffective. If however independent level control is desired, the DUAL routing should be used instead and the inputs wired as parallel. Refer to – Indicators, controls and settings, page 16 Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
(e.g. LP used with a on the rear of the device and full range speaker). ensure that the settings match they types of speakers used. 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...
Page 29
Consider changing the and LIMIT LED is illuminating. thermal conditions, well location of the amplifier and beyond operating check that there is sufficient specifications of 45 ℃. airflow around the amplifier. Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
Check all cable connections for corrosion and the screw terminals to make sure that they have not become loosened. – Check the ground (PE) connection of the system components. 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...
Page 32
Audio limiters, high temperature, DC, HF, short circuit, back‑EMF, peak current limiters, inrush current limiters, mains over/under voltage protection Front status LEDs Signal, limit, fault LEDs per channel; power LED 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...
Page 33
3.6 kg (7.9 lb) ) Test signal for max. output power according IHF‑A‑202 (Dynamic-Headroom, burst 1 kHz / 20 ms on / 480 ms off / low level -20 dB) ) Selectable via Speaker EQ. Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
| Approvals Power amplifier Approvals Regulatory areas Safety EN/IEC/CSA/UL 62368‑1 Immunity EN 55035, EN 61000‑4‑11 Emissions EN 55032, EN 61000‑3‑2, EN 61000‑3‑3, ICES‑003, e‑CFR Title 47 Chapter I Subchapter A Part 15 Subpart B Environment EN/IEC 63000 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...
– Repair & Exchange – Product Security Bosch Building Technologies Academy Visit the Bosch Building Technologies Academy website and have access to training courses, video tutorials and documents: www.boschsecurity.com/xc/en/support/training/ 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...
Page 37
Power amplifier Support and academy | Bosch Security Systems B.V. 2023-01 | V02 | F.01U.402.247 Installation manual...
Page 38
| Support and academy Power amplifier 2023-01 | V02 | F.01U.402.247 Bosch Security Systems B.V. Installation manual...