Page 36 of 66
Agent Greeting Application Upgrades
Mixed Card Group Upgrade
Loadware Upgrade from PC Card (PCMCIA)
NTPH13AA_maint
There are two recommended means of performing multicard application
loadware upgrades in a mixed card group.
1.
Loadware upgrade from a PC Card (PCMCIA).
2.
Loadware upgrade from an external FTP Server.
STEP1: Disable all cards in the group from overlay 32 on the switch
software.
STEP2: FTP into the IP address of the server card. The username and
password are the same as that of the VxWorks shell.
STEP3: Change directory to the "/A:" drive on the card.
STEP4: Change the file transfer type to binary.
STEP5: Copy the new loadware files for both VPS card (NTVQ09AB) and
Media Card (NTVQ09BA) onto the compact flash drive.
STEP6: Log out of the FTP session. Below is an example of transferring
VPS(NTVQ09AB) loadware (vpsLoad.mms) and Media Card
(NTVQ09BA) loadware (mcload) onto the "/A:/" drive of the card.
ftp "<Card IP address>",
Connected to <Card IP address>",.
220 VxWorks FTP server (VxWorks 5.4) ready.
Name (<Card IP address>",:user1): vpsdseuser
331 Password required
Password:
230 User logged in
ftp> bin
200 Type set to I, binary mode
ftp> cd "/A:/"
250 Changed directory to "/A:/"
ftp> put vpsLoad.mms
3.01
February 2006