DIGITAL-LOGIC AG
Operating Temperature
Extended temperature range:
SM800PCX (500MHz)
Security
e1
UL
ETS 301
CE/SEV
Safety
If all signals are externally filtered and assembled into an enclosed metallic case!
EMI / EMC Tests
EMC emission EN61000-6-2:2001
Conducted disturbance
Radiated disturbance
EMC immunity EN61000-6-2
Electrostatic discharge (ESD)
Radiated RF-Field
Electrical fast transients (Burst)
Surge
Conducted disturbances
All information is subject to change without notice.
Specification:
MIL-810-501
MIL-810-502
-40° C to +70°C
Not planned
Not planned
Not planned
Yes
AR385-16
Specification
EN55022 Class B
EN55022 Class B
EN61000-4-2
Voltage = 4kV contact / 8kV air, Criteria A
EN61000-4-3
Level = 10V/m, Criteria A
EN61000-4-4
Grade 2: DC-Power lines
Grade 2: AC-Power lines
Grade 2: Signal lines
Criteria B
EN61000-4-5
Grade 2: DC-Power lines
Grade 2: AC-Power lines
Criteria B
EN61000-4-6
Voltage = 10V coupled by case, Criteria A
MSEBX800/900 Detailed Manual V1.0
= 1000V (5/50ns)
= 2000V (5/50ns)
= 500V (5/50ns)
= 1kV, (1.2/50us)
= 2kV, (1.2/50us)
17