FIGURE 4.2:
16
Services Required
Services

4.5 SMEMA Interfacing

The system is designed in such a way, that it complies with the SMEMA
standards. With every system one SMEMA interface cable (length 200 cm)
will be delivered. If the system needs to work with equipment that is not
supplied by Philips - AAA, this equipment must comply with the SMEMA
standards. The SMEMA cables must be made in advance, according to the
drawing of fig. 4.2 and the specification given below.
Cable specification: 4 wires,
Cable connector for both ends consisting of the following parts per connector:
CPC 14p connector pin: AMP 206044-1
5-pin contacts: AMP 202236-1
cable clamp: AMP 206070-1,
Circuit diagram connector points 1 to 4 must be connected to 1 to 4.
SMEMA interfacing.