Sun2000-450W-P2 Technical Specifications - Huawei SUN2000 User Manual

Smart pv optimizer
Hide thumbs Also See for SUN2000:
Table of Contents

Advertisement

SUN2000 Smart PV Optimizer
User Manual
Technical Specifications
Note a: When the operating temperature of the optimizer ranges from 70℃ to 85℃, the
optimizer may shut down for overtemperature protection and report an overtemperature alarm.
After the operating temperature decreases, the optimizer automatically recovers with no risk of
damage.

5.3 SUN2000-450W-P2 Technical Specifications

Efficiency
Technical Specifications
Maximum efficiency
European weighted efficiency
Input
Technical Specifications
Rated PV module power
Maximum PV module power
Maximum input voltage
MPPT voltage range
Maximum short-circuit current
Overvoltage level
Output
Technical Specifications
Rated output power
Output voltage
Maximum output current
Output bypass
Shutdown output voltage/impedance
Issue 03 (2022-09-20)
Copyright © Huawei Digital Power Technologies Co., Ltd.
SUN2000-450W-P
SUN2000-450W-P2
99.5%
99.0%
SUN2000-450W-P2
450 W
472.5 W
80 V
10–80 V
14.5 A
II
SUN2000-450W-P2
450 W
0–80 V
15 A
Yes
0 V/1 kΩ (±10%)
5 Technical Specifications
22

Advertisement

Table of Contents
loading

Table of Contents