AirMaid 5 000 V Installation And Service Manual

Ozone cleaning system

Advertisement

Quick Links

Installation and service guide for
AirMaid® V ozone cleaning system
A
M
®
i r
A i d
o z o n e c l e A n i n g s y s t e M
i
A
n n o v A t i v e
i r
1
t
r e A t M e n t
5 000 V
10 000 V
20 000 V
30 000 V

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5 000 V and is the answer not in the manual?

Questions and answers

Summary of Contents for AirMaid 5 000 V

  • Page 1 10 000 V 20 000 V 30 000 V Installation and service guide for AirMaid® V ozone cleaning system ® A i d o z o n e c l e A n i n g s y s t e M...
  • Page 3 Supervise children to ensure that they do not play with the device. This manual contains important information about instructions and safety concerning AirMaid® ozone generator (hereinafter referred to as the generator). Read this manual carefully before installation, commissioning or performing service and maintenance on the generator.
  • Page 4: Table Of Contents

    Check that the shipment consists of the components below and that there are no visible damages. Any discrepancy must always be reported to the distributor or manufacturer. Read through the complete guide before starting the installation. 1 x AirMaid® Ozone Generator 1 x AirMaid® Alarm Panel...
  • Page 5: System Overview

    The temperature of supply air should not exceed 40°C. AirMaid® is very effective in reducing odors provided that the reaction time between the ozone and the exhaust air in the kitchen duct is at least 3 seconds. This reaction time is important and must be taken into account during the planning stage.
  • Page 6: Installation Guidelines

    Note that the direction of the airflow must correspond to the arrows on the generator and the pictures below. Make sure that you have selected the correct ozone generator. AirMaid Ozone Capacity Pressure Drop Max Treated Exhaust Airflow through the ozone generator Up to (ΔP @ Target Airflow rate)
  • Page 7 SPLITTING 20000V/30000V OUTLET PIPES BETWEEN DUCTS (OPTIONAL) As the AirMaid 20000V generator has two outlet pipes, it is possible to share the generated ozone between two nearby sections of the exhaust duct system. Because each duct section can have a unique pressure, it is the responsibility of the engineer to ensure the proper airflow is delivered into each section of channel.
  • Page 8: Electrical Connection And Settings

    ASSEMBLY Remove the four screws that fasten the AirMaid® alarm panel to it’s base. Fasten the base to the wall using devices suitable for the wall material. In commercial kitchens place the alarm panel where it will be visable to the staff but not to customers.
  • Page 9: Bacnet Connection And Settings

    Absolent CKV AirMaid BACnet MS/TP Addon Card Product Description: This addon card receives data in JSON –form from the Airmaid panel and makes it visible to other BACNet devices in the same BACNet network. BACnet Standardized Device Profile (Annex L): BACnet Application Specific Controller (B-ASC).
  • Page 10 SYSTEM STATUS Unknown Running Please Call Service Inspect / Clean Offline: Not Connected Offline: Pressure Calibration Fail: Pressure Remotely Disabled OPTIONS INSPECTION INTERVAL Service and maintenance interval in months. SET INSPECTION INTERVAL Change Present Value between 1-12. Default 12 months. TIME LEFT TO INSPECTION Default 360 days.
  • Page 11: Airmaid Startup

    6 AIRMAID STARTUP Once you have adjusted and configured the required airflow and under- pressure, you can then apply power to the generator. The first time the alarm panel is started the time and date must be configured.  ...
  • Page 12 PERFORM HARD RESET: Performs a hard reset of the alarm panel that temporarily shuts down the unit for 5 seconds (from version 3.01). EXIT MENU: Exit the settings menu. SETTINGS MENU FLOW DIAGRAM AIRMAID       5 sec.
  • Page 13 Alarm Panel Hardware and Firmware versions. Press SYSTEM LOAD INFORMATION  Press to display system load values pCalib and pActive. These are diagnostic values that can assist your AirMaid authorized service company to troubleshoot system errors (from version 3.01).
  • Page 14: System Test

    Ensure that there is no leak in the tubing after the ozone generator. If the ozone generator is installed with a filter box, make sure that the filter is clean. Reset the active alarm, see section “6 AIRMAID STARTUP”. If the system still does not start call the distributor or the manufacturer.
  • Page 15: Service And Maintenance

    Switch OFF the main power to the ozone generator and then remove the service hatch from the bottom of the ozone generator. Note: AirMaid® 2000V/5000V has one set of ozone cells; 10000V has two sets; and 20000V has four sets and 30000V has six sets.
  • Page 16: Technical Specifications

    The air-fed AirMaid V generators meet this requirement. Each CGC ozone cell installed in the generators, which is surrounded by a volume flow of up to 54 m3/h, can only clean up to 2500 m3/h total extraction volume. Even with larger total extraction volumes, the AirMaid V generators can...
  • Page 20 Reproduction, modification or translation without a prior written consent is forbidden with the exception of what is permitted by the Act on Copyright. Original Instructions Copyright Information © 2023 Copyright Absolent CKV AB Edition 9 01/23 Distributor: Manufacturer: Absolent CKV AB Email: info@absolentckv.com Propellervägen 4A Internet: www.airmaid.com SE-183 62 Täby, Stockholm Sweden...