Continuous Read Mode - Led Behavior; Table 4-1: Continuous Read Mode - Led Behavior - EMS COBALT C0405 Series Operator's Manual

Table of Contents

Advertisement

4 . 2 . 2
C o n t i n u o u s R e a d M o d e – L E D B e h a v i o r
The table below describes the behavior of the LEDs when the unit is in Continuous
Read Mode (Command 0x0D).
L E D
PWR
COM
COM
RF
C 0 4 0 5 - X X X - 0 1 O P E R A T O R ' S M A N U A L – R E V . 0 3
B E H A V I O R
D E S C R I P T I O N
ON
Controller is powered and functioning
ON
Duplicate Read Delay ≥ 1 and a tag has entered the RF field.
COM LED will remain ON while a tag is in the RF field.
After the tag has exited the RF field the COM light will remain
ON for the duration of the Duplicate Read Delay before turning
OFF
BLINKING
Duplicate Read Delay = 0 and a tag is in the RF field
ON
Continuous Read mode is enabled

Table 4-1: Continuous Read Mode - LED Behavior

C H A P T E R 4 : L E D S T A T U S
Updating Firmware
(Part 2)
After the new firmware has
been copied to internal
memory, the LEDs will blink
ON and OFF repeatedly during
which time the new code is
being written to flash memory.
Warning: do not cancel or
abort this operation, AND do
not unplug or remove power
from the controller under any
circumstance until this
procedure is completed.