3 . 2 . 2
C o n f i g u r a t i o n T a g M e m o r y M a p
Containing a NXP I-CODE SLI IC, the Configuration Tag is a 112-byte ISO 15693
compliant tag that has had much of its memory locked at the factory to prevent
important data from being erased or overwritten. Of the 112 bytes of memory, the first
80 bytes (addresses 0x0000 – 0x0079) are allocated to storing factory default
settings, product ID and manufacturing information. The first 16-bytes (addresses
0x0000 through 0x0015) contain specific data that the controller reads to identify this
special tag.
You are welcome to experiment with the remaining 32 bytes available on this tag
(addresses 0x0080 – 0x0111). All addresses on the Configuration Tag can be read
and no user identifiable information is stored.
3 . 2 . 3
U s i n g t h e C o n f i g u r a t i o n T a g
Re sett i ng t he Co nt rol l e r to D efa u lt Sett i ng s
The Configuration Tag can be used to reset factory defaults to all versions of the
C0405. To restore factory defaults, cycle power to the controller or issue the reset
command (Command 0x35) while the Configuration Tag is in the RF field. Two
seconds after power returns to the C0405, remove the Configuration Tag from the RF
field. The controller will be reset to the following default settings:
CON F IGURATION PARA METER
Command Protocol
Tag Type:
Serial Communications
Node ID
S e t t i n g N od e ID M a n u a l l y ( C 0 4 0 5 - 4 8 5 o n ly)
To set the Node ID on C0405-485 models, cycle power to the controller or issue the
reset command (Command 0x35) while the Configuration Tag is in the RF field. Two
seconds after power returns to the C0405, remove the Configuration Tag from the RF
field. This will set the Node ID value back to the default value of Node ID 00. (Note:
see
Section 4.1 - LED Functions Overview
After power returns to the unit, move the Configuration Tag out of the RF field and
then back into the RF field to increment the Node ID from zero to one.
Removing the Configuration Tag from the controller's RF field and then bringing it
back into the field will increment the Node ID value once each time the Configuration
Tag re-enters the RF field.
C 0 4 0 5 - X X X - 0 1 O P E R A T O R ' S M A N U A L – R E V . 0 3

Table 3-2: Configuration Tag - Controller Defaults

All amber Node LEDs should be off.
0
Amber Node LED 2
should now be lit.
The amber Node LEDs will display, in binary, the Node ID vale assigned to
the controller (See Chapter 4 for more information on LED status).
C H A P T E R 3 : P O W E R & C O M M U N I C A T I O N
D EFAU LT S E T T IN G
ABx Fast – No Checksum
ISO 15693 (I-Code SLI)
9600, N, 8, 1, N (C0405-232 model)
00 (C0405-485 model)
for LED positions and colors).
P A G E 3 3 O F 7 5