Chauvet has no obligation to make, and does not commit to make, any such revisions. Document The Rogue R1 FX-B User Manual is the latest edition of this manual. Go to www.chauvetprofessional.com for the latest version.
Zones for Pixel control ........................... 16 DMX Values ..............................16 Single Control Values ..............................16 Dual Control Movement Values ............................ 23 Dual Control Pixel Values .............................. 26 Operating Settings Configuration ........................27 Home Screen ................................27 Rogue R1 FX-B User Manual Rev. 12...
Important installation or configuration information. Failure to comply with this information may keep the product from working. Useful information. The term “DMX” used throughout this manual refers to the USITT DMX512-A digital data transmission protocol. Rogue R1 FX-B User Manual Rev. 12...
LEDs, contributing to shorter lifespans if always used at full intensity. The Lifespan average LED lifespan is 40,000 to 50,000 hours. To extend LED lifespan, maintain proper ventilation around the product, and limit the overall intensity. Rogue R1 FX-B User Manual Rev. 12...
2. Introduction Description The Rogue R1 FX-B is a fully featured RGBW LED yoke effect beam product with continuous movement of the pan and each of the five autonomous tilt functions. Pixel map the five beams for unique effects. The Rogue R1 FX-B runs on DMX, Art-Net™, sACN, and Kling-Net protocols, and can be controlled with lighting consoles or media servers, providing the ultimate in flexible control integration options.
122 mm 122 mm 122 mm 3.03 in 77 mm 5.83 in 148 mm 9.72 in 247 mm 17.32 in 440 mm 7.05 in 179 mm 3.52 in 89 mm 11.13 in 283 mm Rogue R1 FX-B User Manual Rev. 12...
Power Linking It is possible to link up to 6 Rogue R1 FX-B products at 100 V, 8 products at 120 V, 15 products at 208 V, or up to 16 products at 230 V or 240 V. Never exceed this number.
When mounting the product on the floor, make sure that the product and cables are away from people and vehicles. Place the Rogue R1 FX-B so that it can move freely without hitting anything or anybody. • Leave enough slack on the cabled to prevent tension and pull on the plugs.
Setup Signal Connections The Rogue R1 FX-B can receive DMX, Art-Net™, sACN, or Kling-Net signal. The Rogue R1 FX- B has 2 Neutrik® etherCON® through ports, and 3- and 5-pin DMX in and out ports. For more information about DMX, read the DMX primer at: https://www.chauvetprofessional.com/wp-content/uploads/2016/06/DMX_Primer.pdf.
4. Operation Touchscreen The Rogue R1 FX-B has a touchscreen display as well as 6 control buttons. Navigate the menu structure by pressing the buttons, touching the images of the buttons on the sides of the display, or Control Panel touching the desired menu option on the display directly.
Page 13
0–255 Sets the sACN universe Sets the Kling-Net personality, from KlingNet Personality RGB (15CH) or RGBW (20CH) RGBW In Dual Control mode, the Movement protocol and the Pixel protocol cannot be the same. Rogue R1 FX-B User Manual Rev. 12...
Page 14
Pan Angle 540° tilt range 270° tilt range 180° tilt range Tilt Angle Do not black out while panning/tilting Black out while panning/tilting Keep current settings BL. O. P/T Move Calibrate touchscreen Calibration -10- Rogue R1 FX-B User Manual Rev. 12...
Page 15
_ _ _._ _ _._ Shows current IP address SubMask _ _ _._ _ _._ Shows current Subnet Mask _ _._ _._ _._ Shows current MAC address Error Information No Error!* Shows any errors, or No Error! Rogue R1 FX-B User Manual Rev. 12 -11-...
Page 16
Red 2 Green 2 Blue 2 White 2 Red 3 Green 3 Blue 3 White 3 Red 4 Green 4 Blue 4 White 4 Red 5 Green 5 Blue 5 White 5 -12- Rogue R1 FX-B User Manual Rev. 12...
Operation Protocol Configuration The Rogue R1 FX-B can be set to respond to DMX, Art-Net™, sACN, Kling-Net, or a combination of those protocols. The protocol configuration must be set for the product to respond correctly to the controller(s). See the Menu Map for more information.
Operation Dual Control In Dual Control mode, the Rogue R1 FX-B is controlled by two protocol inputs. One controls the movement of the yoke as well as the dimmer and shutter, while the other controls the individual LED output. Dual Control The Movement protocol controls the movement of the yoke as well as the dimmer and shutter.
Use <LEFT> or <RIGHT> to select the digit to be altered. Use <UP> or <DOWN> to increase or decrease the number value of that digit. Repeat until the universe is set as desired. Press <ENTER>. Rogue R1 FX-B User Manual Rev. 12 -15-...
– Continuous Tilt 4 Stop 129255 Clockwise rotation, slow to fast No function 001127 Counterclockwise rotation, slow to fast – – – Continuous Tilt 5 Stop 129255 Clockwise rotation, slow to fast -16- Rogue R1 FX-B User Manual Rev. 12...
Page 22
190204 Strobe 8 (Random pulse), fast to slow 205209 On 210224 Strobe 9 (Fade in, fade out), fast to slow 225229 On 230244 Strobe 10 (Random pulse), fast to slow 245255 On -18- Rogue R1 FX-B User Manual Rev. 12...
Page 23
117124 Color 14 125133 Color 15 134185 No function 186207 Rainbow effect, fast to slow 208213 Stop 214235 Reverse Rainbow effect, fast to slow 236240 No function 241255 Color jump, fast to slow Rogue R1 FX-B User Manual Rev. 12 -19-...
Page 25
226230 Auto program 19 231235 Auto program 20 236240 Auto program 21 241245 Auto program 22 246250 Auto program 23 251255 Auto program 24 (cycle 1–23) LED Macro Speed 000255 Slow to fast Rogue R1 FX-B User Manual Rev. 12 -21-...
Page 26
Tilt 4 000255 0–100% – – – Fine Tilt 4 000255 0–100% No function 001127 Counterclockwise rotation, slow to fast – – – Continuous Tilt 4 Stop 129255 Clockwise rotation, slow to fast -22- Rogue R1 FX-B User Manual Rev. 12...
001127 Counterclockwise rotation, slow to fast – Continuous Tilt 3 Stop 129255 Clockwise rotation, slow to fast No function 001127 Counterclockwise rotation, slow to fast – Continuous Tilt 4 Stop 129255 Clockwise rotation, slow to fast Rogue R1 FX-B User Manual Rev. 12 -23-...
Page 29
115119 Link all heads to head 1 120124 Unlink all heads from head 1 125134 No function (reserved for future use) 135139 Dimmer speed mode fast 140144 Dimmer speed mode smooth 145255 No function Rogue R1 FX-B User Manual Rev. 12 -25-...
Operating Settings Configuration Home Screen The Rogue R1 FX-B has a home screen that shows the current control protocols, personalities, starting addresses, IP addresses, and universes. To see the home screen, press <MENU> repeatedly until it shows on the display. From the home screen, touch any of the displayed control settings to immediately jump to that part of the menu, such as the personality, starting address, or universe, or press <ENTER>...
Operation Network Settings IP Mode The IP address of the Rogue R1 FX-B can be set manually, by the network, or to a pre-set static address specific to each product. To set the IP Mode, follow the instructions below: Navigate to the Setup menu.
Use <UP>, <DOWN>, <LEFT>, or <RIGHT> to select NO (display will respond to touch) or YES (display will not respond to touch), or touch the display where it says the desired option. Press <ENTER>. Rogue R1 FX-B User Manual Rev. 12 -29-...
Loss of Data In case of an input signal being lost in any way, the Rogue R1 FX-B will respond in one of two ways. the product will either hold the last signal received, or black out all LED output.
PRESET C and press <ENTER>. When you make that selection, the product will reset automatically. Go back and make the changes you need to make in the menu. This will automatically save to the preset you are in. Rogue R1 FX-B User Manual Rev. 12 -31-...
Press <ENTER>. System Information All information about the current status of the Rogue R1 FX-B is available through the product’s Sys Info menu. To view this information, follow the instructions below: Press <MENU> repeatedly until the Home Screen shows on the display.
MAC Address To assign the fourth, fifth, or sixth digit of the MAC address, follow the instructions below: 1. Use <UP> or <DOWN> to select MAC4, MAC5, or MAC6. 2. Press <ENTER>. 3. Use <UP> or <DOWN> to increase or decrease the value, from 000–255. 4. Press <ENTER>. Rogue R1 FX-B User Manual Rev. 12 -33-...
Connect the Rogue R1 FX-B to a computer with an ethernet cable. Verify the network with the Rogue R1 FX-B is connected to the computer. Step 2 Set the control protocol on the Rogue R1 FX-B to ArtNet in Single Control mode. (See Single Control Protocol) Set the IP Mode to Static.
Page 39
Type 2.255.0.0 into the IP address bar. Press <Tab> on your keyboard. The Subnet mask bar should automatically populate as 255.0.0.0. If not, then enter it manually. Ignore the Default gateway bar. Rogue R1 FX-B User Manual Rev. 12 -35-...
Page 40
Information) and checking that the version number matches the name of the file on the computer. Step 13 Disconnect the Rogue R1 FX-B from the computer. The firmware update is complete. The examples shown are for illustrative purposes. -36- Rogue R1 FX-B User Manual Rev. 12...
Gently polish the lens surfaces until they are free of haze and lint. Always dry the external surfaces thoroughly and carefully after cleaning them. Do not spin the cooling fans by blowing compressed air into them. Rogue R1 FX-B User Manual Rev. 12 -37-...
For warranty terms and conditions and return information, please visit our website. Returns For Customers in the United States and Mexico: www.chauvetlighting.com/warranty- registration. For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu/warranty-registration. Rogue R1 FX-B User Manual Rev. 12...