  • Page 1 Carbon Monoxide Alarm (Type B) User Manual 1008 EN 50291-1:2018 Importer: Model: XC01/XC05P/XC01P-R Sense Europe B.V. EN/DE/FR/NL) Parellaan 2H, 2132 WS Hoofddorp, the Netherlands F.1.05.XC0501 Phone Number: +31 (0)85-0043.903...
  • Page 2 Contents English 01-27 Deutsch 28-56 Français 57-85 Nederlands 86-118...
  • Page 3 This user manual contains important information regarding the installation and operation of your carbon monoxide alarm. Please take a few minutes to thoroughly read this manual which should be saved for future reference. If you are installing the carbon monoxide alarm for use by others, you must leave this manual—or a copy of it—with the end user. Introduction This device is a battery-powered standalone CO (carbon monoxide) alarm with an advanced electrochemical sensor for domestic use.
  • Page 4: Package Contents

    Package Contents Battery Status Peak Concentration 1 × CO Alarm 2 × Screws Indication 2 × Anchor Plugs 1 × User Manual CO Concentration Test/Silence Button The Test/Silence button is used to test the unit's electronics and to silence the unit during an alarm. When testing the alarm Product Features weekly, press and hold the test button and you will hear a short beep, indicating that the alarm has entered the test mode.
  • Page 5 30 ppm over 120 minutes, WARNING 50 ppm for 60–90 minutes, THIS DEVICE IS DESIGNED TO PROTECT INDIVIDUALS FROM ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE. IT MAY 100 ppm for 10–40 minutes, NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN DOUBT, CONSULT A MEDICAL PRACTITIONER.
  • Page 6: Where To Install

    • The CO alarm should have a horizontal distance between 1 m (3.3 feet) and 3 m (10 feet) from any potential CO source. Where to Install • If there is a partition in the room, the CO alarm should be installed on the same side of the partition as the potential CO source. Ideally, a carbon monoxide alarm should be installed in every room containing a fuel-burning appliance, and one in every 300 mm (11.8 in) bedroom.
  • Page 7: Locations To Avoid

    2. Installing the CO alarm in a bedroom or room without a fuel-burning appliance (see Figure 2): NOTE: Due to the product’s unique design and unfixed installation, it is not recommended to install it on a ceiling, as it is prone to falling off and causing injuries to people.
  • Page 8: Installation Method

    6. In extremely humid areas. This alarm should be at least 3 m (10 feet) from a bath or shower, sauna, humidifier, vaporizer, dishwasher, laundry room, utility room or other sources of high humidity. 7. In areas where the temperature is colder than 4°C (40°F) or hotter than 38°C (100°F). For example, non-air-conditioned crawl spaces, unfinished attics, uninsulated or poorly insulated ceilings, porches and garages.
  • Page 9 Follow the process below to open the battery compartment cover: Wall Mounting 1. Choose a suitable installation location by referring to the “Where to Install” section. Hold the alarm with both hands and put your thumbs on both ends of the battery compartment cover. Then, push the cover upwards with some force to remove it.
  • Page 10 3. Insert the anchor plug into the screw hole and hammer it in until the head of the anchor plug is flush with the wall. Installation on a Table 4. Use the two provided screws or 3.5 × 25 mm countersunk screws to screw into the two anchor plugs. Be sure to leave a 5 The base of the detector has two feet built into the design that allow it to stand freely on a flat surface.
  • Page 11: Alarm Testing

    Each time you push the test button, the LCD displays the peak CO concentration recorded since the previous reset. The peak Alarm Testing CO concentration will be displayed for 5 seconds, and then the device will enter standby mode. In the example, 300 ppm was the maximum CO concentration recorded since the unit was last reset.
  • Page 12 While detecting CO, the LCD will display different indicators to inform you of the alarm status, as shown below: A CO concentration level None. Dangerous CO concentration is Mode LCD Display LED Indicator Audible Alarm Remarks ranging from 30 to 999 ppm detected, but has not reached has been detected, but for the alarm status.
  • Page 13: Technical Specifications

    Flashes red 4 times None. CO silence mode: After 9 Flashes yellow 2 times 2 beeps every 60 Please clean your alarm and see if it is Silence Mode Fault every 6 seconds. minutes, the unit will exit working normally. If "Err" continues to every 60 seconds.
  • Page 14: Maintenance

    appliance technician to investigate sources of CO from fuel-burning equipment and appliances, and inspect for proper Safety Standard EN 50291-1:2018 operation of this equipment. 4–38°C (40–100°F) Operating Temperature 4. If problems are identified during this inspection, have the equipment serviced immediately. Note any combustion equipment that has not been inspected by the technician and consult the manufacturer’s instructions, or contact the manufacturers Operating Relative Humidity 10%–85% RH (non-condensing)
  • Page 15: Limitations Of Co Alarms

    WARNING 2. This CO alarm will not sense carbon monoxide that does not reach the sensor. This CO alarm will only detect CO that reaches the sensor. CO may be present in other areas. Doors or other obstructions may affect the rate at which CO reaches DO NOT TAMPER WITH THE APPARATUS, AS THERE IS A RISK OF ELECTRIC SHOCK OR MALFUNCTION.
  • Page 16: Environmental Protection

    Warranty Thank you for purchasing our product. X-Sense Pro provides a 5-year worry-free guarantee from the date of purchase. If you have any questions, please feel free to contact the dealers or distributors in your region. They will get back to you within 1-3 working days.