Each DIVAR IP all-in-one 6000 unit is delivered with the default user name ADMIN and with an
initial password. The initial password is unique for each unit. You can find it on the label at the
rear of the unit, below the IPMI port.
Bosch strongly recommends to change the initial password during the IPMI configuration, and
to store the new password at a secure location.
Notice!
i
For security reasons, do not permanently connect the device to a public network through the
IPMI port.
To configure the IPMI settings:
1.
2.
3.
4.
5.
6.
7.
7.3

Replacing a faulty hard drive and configuring a new hard drive

If a hard drive that is installed on your DIVAR IP all-in-one 6000 system is faulty, the respective
hard drive tray LED is illuminated red. In this case, you must do the following:
1.
2.
Notice!
i
This procedure only applies to a default RAID5 configuration and only in the case that a single
hard drive in the RAID5 configuration is faulty. Only in this case it can be ensured that no data
will be lost.
Notice!
Bosch is not liable for any data loss, damages, or system failures of units equipped with hard
i
drives that are not supplied by Bosch. Bosch cannot provide support if non-Bosch-supplied
hard drives are considered to be the cause of the problem. To troubleshoot potential
hardware issues, Bosch will require Bosch-supplied hard drives to be installed.
7.3.1

Replacing a faulty hard drive

To replace a faulty hard drive:
4
7.3.2

Rebuilding RAID5 with the new hard drive

Automatic RAID5 rebuild
1.
2022-10 | V01 | F.01U.408.604
Turn on the unit and press Del to enter the BIOS setup.
In the BIOS setup, navigate to the tab IPMI.
Select the option BMC Network Configuration, then press Enter.
In the next dialog box, select the option Update IPMI LAN Configuration, then press
Enter.
The Update IPMI LAN Configuration dialog box is displayed.
In the Update IPMI LAN Configuration dialog box, select Yes, then press Enter.
Set the desired network configuration parameters.
Press F4 and Enter to save and exit.
The DIVAR IP all-in-one 6000 unit restarts.
Replacing a faulty hard drive, page 18 .
Rebuilding RAID5 with the new hard drive, page 18 .
Remove the faulty hard drive from the unit and install the new hard drive.
Refer to chapter Installing a SATA hard drive in the Installation manual.
On the DIVAR IP all-in-one desktop, double-click the Launch LSA shortcut.
The LSI Storage Authority application starts and the Remote Server Discovery page is
displayed.