Service Level Parameters
Description:
SCL
2
Readout scale.
SPL
-1
Minimum limit for Temperature Set Point (SP)
SPH
5
Maximum limit for Temperature Set Point (SP)
SP
0
Temperature setpoint to be achieved.
C-H
REF
Temperature control mode.
HYS
3
Off / On thermostat differential.
CRT
2
Compressor rest time.
CT1
6
Compressor run time with faulty T1 probe.
CT2
2
Compressor off time with faulty T1 probe.
CSD
1
Compressor stop delay after door has been opened. (Only if DS = YES).
DFM
TIM
Defrost start mode.
DFT
4
Time interval between defrosts in hours
DFB
YES
Defrost timer clock.
DLI
10
Defrost end temperature (Only if T2 = YES).
DTO
15
Maximum defrost duration.
DTY
OFF
Defrost type.
DPD
0
Evaporator pump down. Timed pause at start of defrost.
DRN
1
Drain down period.
DDM
SP
Defrost display mode.
DDY
10
Defrost display delay period.
FID
YES
Evaporators Fans operate in defrost.
FDD
5
Evaporator fan restart temperature following defrost. (Only if T2 = YES).
FTO
2
Maximum evaporator fan stop period following defrost.
FCM
NON
Evaporator fan mode during thermostatic control.
FDT
-1
Te-Ta difference for fans to turn off after compressor stopped. (Only if T2 = YES and FCM = TMP).
FDH
3
Temperature differential for evaporator fan restart. (Only if T2 = YES and FCM = TMP).
FT1
15
Fan stop delay after compressor stop.
FT2
3
Timed fan stop following FT1. (With FT2 = 0 the fans remain on all the time).
FT3
2
Timed fan run following FT2. (With FT3 = 0 & FT2 > 0 the fans remain off all the time).
ATM
REL
Alarm threshold configuration.
ALA
-2
Low temperature alarm threshold.
AHA
8
High temperature alarm threshold.
ALR
-5
Low temperature alarm differential. (With ALR = 0 the low temperature alarm is excluded).
AHR
8
High temperature alarm differential. (With AHR = 0 the low temperature alarm is excluded).
ATI
T3
Alarm probe.
ATD
90
Delay before alarm temperature warning.
ADO
8
Delay before door open alarm warning.
AHM
ALR
Operation in case of high condenser alarm.
AHT
65
Condenser alarm temperature (T3 = CND).
ACC
0
Condenser cleaning period. (With ACC = 0 condenser cleaning is disabled).
IISM
NON
Switchover method to 'Mode 2'
IISL
1
Minimum limit for Mode 2 Temperature Set Point
IISH
1
Maximum limit for Mode 2 Temperature Set Point
IISP
1
Temperature setpoint to be achieved in 'Mode 2' .
IIHY
4
Off / On thermostat differential in 'Mode 2' .
IIFC
NON
Evaporator fan mode during 'Mode 2' thermostatic control.
HDS
3
Controller sensitivity for switch over between 'Modes' 1 and 2. (1 = minimum, 5 = maximum).
IIDF
6
Time interval between defrosts in 'Mode 2' .
8