Four Steps to extend the life of your appliance Getting to know your new Foster appliance Installation Using the appliance Maintenance www.fosterrefrigerator.com...
Page 3
All installations must conform to local and municipal regulations and directives. In case of doubt contact your Foster authorised distributor or the Foster Technical Department. The information contained in this manual is current at the time of publication and is subject to change without notice.
Climate Class Climate class indicated on the serial plate shows the ambient temperature & humidity at which this appli- ance has been tested, for the purposes of establishing values in line with European standards. Climate Class Temperature Relative humidity 25˚C Where the product is operated outside the design conditions above excess condensation may occur particularly on (though not limited to) the doors and end panels.
Disposal of this appliance should be carried out by a suitably licensed waste contractor in accordance with national laws and regulations which may be in force at the time. FMPRO & FMSLIM Multideck - User Manual...
Installation Removal of packaging Prior to carrying out this operation please ensure that these instructions have been read, understood and that the necessary personnel and tools are available to ensure that these instructions are complied with. It is also recommended that a full assessment of the installation conditions and requirements be conducted prior to commencing this operation.
Page 7
These should not be removed. Ensure that all packaging is disposed of in an appropriate way in accordance with any local regulations for waste disposal. FMPRO & FMSLIM Multideck - User Manual...
Page 8
Start-Up and Test Sequence After unpacking, clean (cleaning directions supplied within this manual) and allow the appliance to stand for 60 minutes before turning on. Ensure the appliance is situated on a firm, level surface, away from both hot and cold air sources, as this will affect its performance.
Pressing button 1 for 3 seconds will turn the unit on or into standby. When in standby the display will only display ‘ - ‘ . The remainder of the display will be blank. When operating normally, the display will show the internal temperature of the cabinet. FMPRO & FMSLIM Multideck - User Manual...
‘Loc’ . If button 1 is not pressed the new value will not be stored. Exit by pressing button 3. If the Set Point cannot be adjusted to the value required please contact your authorised Foster dealer for advice.
Always ensure air can circulate around/through the stored product. It is important that for optimum energy and temperature performance that adequate airflow is maintained around the perimeter of the shelves, and around all stored products. FMPRO & FMSLIM Multideck - User Manual...
Page 12
The shelf positions can be adjusted to suit specific requirements by following the procedure outlined below; Note - We recommend that at least 2 people carry out these instructions. Some items have been removed from the images to aid clarity. Lift the shelf and disconnect the undershelf lighting if fitted.
1. While the fault is still present icon ‘a’ will continue to be illuminated and the display will cycle between the fault code and the appliance temperature. FMPRO & FMSLIM Multideck - User Manual...
6 to 12 months to maintain your warranty and ensure optimal performance of your appliance. We recommend that service is 6-12 MONTHS carried out by an authorised Foster agent or by contacting the Foster Service team using the contact details in this manual. www.fosterrefrigerator.com...
Page 15
The interior of the appliance should be cleaned with warm soapy water and a non abrasive cloth then rinsed with a clean cloth, clean water and dried. FMPRO & FMSLIM Multideck - User Manual...
Service to arrange for this to be replaced. During this time the appliance cannot maintain an accurate temperature and all product should be removed and the appliance switched off. tE - This indicates that the evaporator probe has failed. Call your authorised dealer or Foster Service to arrange for this to be replaced.
Page 17
If the reason for the malfunction cannot be identified, disconnect the electrical supply from the appliance and contact your authorised dealer or Foster Service. When requesting a service call, please quote the model and serial number which can be found on the inside of the appliance on the right hand wall and begins with ‘E’...
Page 19
Notes: FMPRO & FMSLIM Multideck - User Manual...
Page 20
By Appointment to Her Majesty Queen Elizabeth II Suppliers of Commercial Refrigeration Foster Refrigerator, King’s Lynn For more information: For service and spares: +44 (0) 1553 698485 For service +44 (0) 1553 780333 regional@foster-gamko.com service@foster-gamko.com fosterrefrigerator.com For parts +44 (0) 1553 780300 parts@foster-gamko.com...