8.4 Power outputs testing procedure

Disconnect the devices
from the remote control outputs
Power up the receiver unit
Press the red mushroom-head button
Disengage the red mushroom-
head button and press the green
button on the receiver unit
Test the manual commands by
pressing the push-buttons on
the receiver one by one
Use a tester or pilot lamp to
directly test the outputs of the
radio remote control, by
pressing the manual commands
9. F
REQUENTLY
T
T
HE
RANSMITTER IS NOT WORKING
R
.
ECEIVER
Make sure that:
• The receiver power supply is correct both in terms of voltage (9 - 28 V) and
polarity;
•The red emergency button of the receiver is not pressed, and that you have
pressed the green reset button;
The receiver is not installed in a metal housing;
• The LED on the transmitter lights when any of the commands is pressed. If not,
make sure that the battery is present and charged, and replace it if necessary.
• The receiver has been programmed correctly. To be certain, repeat the steps
described in the section PROGRAMMING PROCEDURES;
• The controlled devices function correctly if powered directly, cutting out the radio
remote control, and if they have no short-circuits;
T
T
HE
RANSMITTER WAS DROPPED AND NOW IT DOESN
Make sure that:
• The transmitter battery is still in its compartment;
• The battery connection is intact and ensures electrical contact;
Power outputs test procedure
Start
Restore by repairing or replacing the
cables or part thereof. Check any
continuity interruptions you may find
Check the electrical continuity through
the wiring and connectors connecting
the devices to thre remote control
outputs; also make sure that all screws
present are firmly tightened
commands all
their rispective
No
A
Q
SKED
,
OR WORKS ONLY AT A SHORT DISTANCE FROM THE
O.M.F.B. S.p.A. Hydraulic Components
We reserve the right to make any changes without notice.
Edition 2003.06 No reproduction, however partial, is permitted.
Via Cave, 7/9 25050 Provaglio d'Iseo (Brescia) Italy Tel.: +39.030.9830611
Fax: +39.030.9839207-208 Internet:www.omfb.it e-mail:contatti@omfb.it
USER MANUAL
device or devices that are not working
Yes
Do the
Yes
manual
Check the operation of the individual
activate
devices, using a tester or powering them
outputs?
Request a return indicating "Possible
problems on the power outputs"
UESTIONS
'
T WORK
pag.46
Reconnect the devices to thre remote
control outputs and make sure the
system works properly
Restore by repairing or replacing the
No
Do the devices
all work if
powered
directly?
directly from the battery
.