(6) Warning Level (Default Version)

PM warning level 0 to 5 as shown below is programmed according to the amount of accumulated PM to prompt
the operator to perform the required procedure in each level.
• Level 0: Normal operation. Regeneration is not required.
• Level 1: Auto Regeneration is possible in the Auto Regeneration Mode.
• Level 2: Auto Regeneration is possible in the Auto Regeneration Mode. Parked Regeneration is possible in both
of the Auto Regeneration Mode and Inhibit Mode.
• Level 3: Auto Regeneration is not possible in above level 3. Parked Regeneration is required as soon as possible.
• Level 4: Only by using diagmaster, Parked Regeneration is possible. Parked Regeneration is required as soon
as possible.
• Level 5: Replacement is required. Regeneration is not possible.
Auto Regeneration Mode
Engine
Warning
Buzzer
output
level
limitation
No
0
No
limitation
No
1
No
limitation
Every 5
2-1
seconds
No
limitation
Every 3
2-2
seconds
Every
3
50 %
second
Every
4
50 %
second
Every
5
50 %
second
 : OFF,  : Blink,  : ON
1-M18
Remark
Normal operation, Regeneration is not required.
Under the Auto Regeneration or preparation for Auto
Regeneration.
Initiation condition for Regeneration is not satisfied.
(Coolant temperature and Voltage are below threshold.)
Keep on working and increase the engine rpm until
regeneration indicator stops flashing and remains constant
"ON".
Under the Auto Regeneration or preparation for Auto
Regeneration.
Initiation condition for Regeneration is not satisfied.
(Coolant temperature and Voltage are below threshold.)
Keep on working and increase the engine rpm until
regeneration indicator stops flashing and remains constant
"ON".
Condition for Parked Regeneration is not satisfied.
Condition for Parked Regeneration is satisfied. When
pressing the parked regeneration switch, Parked
Regeneration will start.
Under the preparation for Parked Regeneration.
Initiation condition for Regeneration is not satisfied.
(Coolant temperature and Voltage are below threshold.)
Under the Parked Regeneration.
Without diagmaster.
Condition for Parked Regeneration is not satisfied.
Condition for Parked Regeneration is satisfied. When
pressing the parked regeneration switch, Parked
Regeneration will start.
Under the preparation for Parked Regeneration.
Initiation condition for Regeneration is not satisfied.
(Coolant temperature and Voltage are below threshold.)
Under the Parked Regeneration.
Even when using diagmaster, it is not possible to do Parked
Regeneration.
ENGINE
9Y1210822ENM0037US0
9Y1210822ENM0038US0