Overview Of Heater Design - Dyna-Glo DELUX KFA50DGDR User Manual

Kerosene portable forced air heaters
Table of Contents

Advertisement

NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
5. OVERVIEW OF HEATER'S DESIGN
Fuel System: This heater is equipped with an electric
air pump that forces air through the air
line connected to the fuel intake and then
through a nozzle in the burner head.
When the air passes in front of the fuel
intake it causes fuel to rise from the tank
and into the burner nozzle. This fuel and
air mixture is then sprayed into the
"Sure Fire Ignition" : The electronic ignitor sends voltage to a specially designed spark plug.
The Air System : The heavy duty motor turns a fan that forces air into and around the combustion chamber.
The Safety System :
A. Temperature Limit Control : This heater is equipped with a Temperature Limit Control designed to turn
MODELS
KFA50DGDR
KFA80DGDR
KFA135DGDR
KFA180DGDR
KFA220DGDR
B. Electrical System Protection : This heater's electrical system is protected by a fuse mounted to the PCB
C. Flame-Out Sensor :
The spark plug ignites the fuel and air mixture described above.
Here the air is heated and then forced out the front of the heater.
off the heater should the internal temperature rise to an unsafe level. If this
device activates and turns your heater off it may require service.
Internal Shut-Off Temp.
Plus/Minus 10 Degrees
assembly that protects it and other electrical components from damage.
FUSE TYPE:
176˚F/80˚C
158˚F/70˚C
158˚F/70˚C
230˚F/110˚C
194˚F/90˚C
All Models
7
Reset Temperature
Plus/Minus 10 Degrees
122˚F/50˚C
104˚F/40˚C
104˚F/40˚C
194˚F/90˚C
140˚F/60˚C
e as needed.
125 volt / 8 amps
normal operation.

Advertisement

Table of Contents
loading