Dyna-Glo WORKHORSE Series User's Manual And Operating Instructions
Dyna-Glo WORKHORSE Series User's Manual And Operating Instructions

Dyna-Glo WORKHORSE Series User's Manual And Operating Instructions

Advertisement

Quick Links

INDOOR/OUTDOOR PRODUCTS
KEROSENE PORTABLE
FORCED AIR HEATERS
"USER'S MANUAL AND
OPERATING INSTRUCTIONS"
MODEL : KFA50WH / KFA75WH / KFA125WH
Before the first use of this heater, please read this USER'S MANUAL very
carefully. This USER'S MANUAL has been designed to instruct you as to
the proper manner in which to assemble, maintain, store, and most
importantly, how to operate the heater in a safe and efficient manner.
Please keep this manual for future reference.
CONSUMER : Retain this manual for future reference.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:30 a.m. - 4:30 pm CST, Monday - Friday.
or email us at customerservice@ghpgroupinc.com
KFA170WH / KFA210WH
COMPLIES WITH UL733 AND
ANSI A10.10-1998
CAN/CSA/B140.0-03 AND CSA
B140.8-1967
IMKFAWH-GCU

Advertisement

Table of Contents
loading

Summary of Contents for Dyna-Glo WORKHORSE Series

  • Page 1 INDOOR/OUTDOOR PRODUCTS KEROSENE PORTABLE FORCED AIR HEATERS “USER’S MANUAL AND OPERATING INSTRUCTIONS” COMPLIES WITH UL733 AND ANSI A10.10-1998 CAN/CSA/B140.0-03 AND CSA B140.8-1967 MODEL : KFA50WH / KFA75WH / KFA125WH KFA170WH / KFA210WH Before the first use of this heater, please read this USER’S MANUAL very carefully.
  • Page 2: Risk Of Electric Shock

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! DANGER: : IMPROPER USE OF THIS HEATER CAN RESULT IN SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR CARBON MONOXIDE POISONING. WARNINGS: 1. RISK OF INDOOR AIR POLLUTION! Use this heater only in well ventilated areas. Provide at least a three-square foot (2,800 sq. cm.) opening of fresh outside air for each 100,000 BTU/hr.
  • Page 3 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! CONTENTS OF USER’S MANUAL ITEM PAGE # 18&21&24 19,20&22,23&25,26 1. INTRODUCTION Please read this USER’S MANUAL carefully. It will show you how to assemble, maintain, and operate the heater safely and efficiently to obtain full benefits from its many built-in features. 2.
  • Page 4 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Front Handle Rear Handle Upper Shell Hot Air Outlet Shell Lower Cord Wrap Fuel Gauge BTU Control Switch Fuel Cap (170WH Model Only) Side Cover Pressure Gauge Lamp Fan Guard Thermostot Knob Room Temp. Display Power Cord (170WH Model Only) (Piggy Back)
  • Page 5: Unpacking And Assembly

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 3. UNPACKING AND ASSEMBLY 1. REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX. (Fig. 4 and 5) NOTE : Save the shipping carton and packing materials for future storage. KFA50WH KFA170WH KFA125WH KFA210WH KFA75WH...
  • Page 6 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 2. ASSEMBLY Screw Handle Front Guard For KFA50WH/75WH Models only (Assembly time for this product is 3 minutes) Wedged Portion Tools Required Slit Hole Medium Phillips Screwdriver. 1) Lift front guard for arrow direction and make sure that guard’s wedged portion fits into the slit hole on the upper housing.
  • Page 7 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Front Handle Screw Cap Nut S Rear Handle Hot Air Outlet Cord Wrap Flange Screw Fuel Tank Flange Air Inlet Wheel Support Frame Threaded Axle Wheel Wheel Bushing Cap Nut L Figure 7. Assembling Handle, Wheel and Cord wrap CAUTION : DO NOT OPERATE heater without support frame assembled to tank.
  • Page 8 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 5. OVERVIEW OF HEATER’S DESIGN Fuel System : This heater is equipped with an electric air pump that forces air through the air line connected to the fuel intake and then through a nozzle in the burner head. When the air passes in front of the fuel intake it causes fuel to rise from the tank and into the burner nozzle.
  • Page 9: Fueling Your Heater

    NEVER LEAVE THE HEATER 6. FUELING YOUR HEATER NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE : FILL THE TANK OUTDOORS. DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED. IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER : The first time you light the heater, it should be done outdoors.
  • Page 10 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NOTICE : The major electrical components of this heater are protected by a safety fuse mounted to the PCBboard. If your heater fails to start, check this fuse first and replace as necessary. You should also check your power source to insure that proper voltage and frequency are being supplied to the heater.
  • Page 11 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 9. MAINTENANCE WARNING!! : NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR WHILE HOT! USE ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of third party or other alternate components will void warranty and may cause unsafe operating conditions.
  • Page 12 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! E.) NOZZLE REMOVE DIRT IN NOZZLE AS NEEDED (SEE PAGE 16). Combustion Chamber Screw (For KFA50WH/75WH/125/170WH Models Only) - Remove upper shell (See page 10). Ignitor Wire - Remove fan blade (See page 10). - Remove fuel and air line hoses from nozzle adaptor.
  • Page 13 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Screw F.) SPARK PLUG CLEAN AND REGAP EVERY 600 HOURS OPERATION OR REPLACE AS NEEDED. (For KFA50WH/75WH/125/170WH Models Only) Spark Plug - Remove upper shell (See page 10). - Remove fan (See page 10). Ignitor Wire - Remove ignitor wire from spark plug.
  • Page 14: Pump Pressure Adjustment

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! H.) FUEL FILTER Fuel Filter CLEAN OR REPLACE TWICE A HEATING Fuel line SEASON OR AS NEED. - Remove side cover screws using medium phillips screwdriver. Switch Wires - Disconnect switch wires from power switch and remove side cover.
  • Page 15: Replacing Fuse

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 10. REPLACING FUSE NOTICE : This heater is fuse protected. If your heater fails to ignite, DO NOT RETURN YOUR HEATER TO THE STORE. Please follow the simple instructions below to inspect and change the fuse. PROCEDURE FOR REPLACING FUSE WARNING : SHOCK HAZARD To prevent personal injury, unplug the power cord before replacing fuse.
  • Page 16: Troubleshooting Guide

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 11. TROUBLE SHOOTING GUIDE TROUBLE POSSIBLE CAUSE CORRECTIVE ACTION Heater ignites but MAIN PCB 1. Wrong pump pressure 1. See Pump Pressure Adjustment, assembly shuts heater off after Page 13. a short period of time. 2.
  • Page 17: Wiring Diagram

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 12. WIRING DIAGRAM A) WIRING DIAGRAM (KFA50WH Model) CONTROL PCB DISPLAY PCB SPARK PLUG BLACK IGNITOR POWER LAMP (LED) BLACK ORANGE BLACK PUMP WHITE MOTOR CAPACITOR GREEN 15uF/230VAC PW-W/H EARTH PW-BLK BLACK PHOTO CELL BLACK POWER LIMIT...
  • Page 18: Specifications

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 13. SPECIFICATIONS 32.0"(813mm) 11.7"(297mm) KFA50WH/75WH Models KFA170WH KFA125WH KFA210WH 47.4"(1,205 mm) 41.9"(1,063 mm) 21.5"(547 mm) 23.1"(587 mm) 32.4"(824 mm) 33.5"(850 mm) KFA125/170/210WH Models MODEL KFA50WH KFA75WH KFA125WH KFA170WH KFA210WH HIGH 50,000 75,000 125,000 170,000 210,000 BTU/Hr.
  • Page 19 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 14. EXPLODED PARTS DRAWING (KFA50WH/75WH Models Only) NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS. 22-3 22-8 22-5 22-7 22-2 22-1 22-4 22-6 24 14 25-2 25-5 25-6 25-7 25-9 25-8 25-11 25-1...
  • Page 20 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA50WH/75WH Models Only) PART NO. Quantity KEY NO. DESCRIPTION KFA50WH KFA75WH Fuel Tank Assmebly 2151-0026-00 2151-0027-00 Fuel Drain-Bolt Fuel Gauge 2156-0047-00 2156-0049-00 Fuel Filter Assmbly 2155-0005-00 2155-0005-00 Fuel Cap 2151-0041-00 2151-0041-00 Cord Bushing 3712-0013-00...
  • Page 21 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA50WH/75WH Models Only) PART NO. Quantity KEY NO. DESCRIPTION KFA50WH KFA75WH 25-13 Lint Filter See SP-KFA1005 See SP-KFA1005 25-14 Bolt Flange 4329-0016-00 4329-0016-00 25-15 Output Filter See SP-KFA1005 See SP-KFA1005 25-16 End Filter Cover 3221-0029-00...
  • Page 22 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 14. EXPLODED PARTS DRAWING (KFA125/170WH Models Only) NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS. 20-3 20-8 20-5 20-7 20-2 20-1 20-4 20-6 22 12 23-2 23-5 23-6 23-7 23-9 23-8 23-11 23-1...
  • Page 23 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA125/170WH Models Only) PART NO. Quantity KEY NO. DESCRIPTION KFA125WH KFA170WH Fuel Tank Assmebly 2151-0028-00 2151-0029-00 Fuel Drain-Bolt 4329-0072-00 4329-0072-00 Fuel Gauge 2156-0050-00 2156-0051-00 Fuel Filter Assmbly 2155-0001-00 2155-0001-00 Fuel Cap 2151-0041-00 2151-0041-00 Cord Bushing...
  • Page 24 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA125/170WH Models Only) PART NO. Quantity KEY NO. DESCRIPTION KFA125WH KFA170WH 23-15 Output Filter See SP-KFA1005 See SP-KFA1005 23-16 End Filter Cover 3221-0029-00 3221-0076-00 23-17 Ball See SP-KFA1010 See SP-KFA1010 23-18 Spring See SP-KFA1010...
  • Page 25 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 14. EXPLODED PARTS DRAWING (KFA210WH Model Only) NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS. 20-8 20-3 20-7 20-1 20-5 20-2 20-4 20-6 20 21 23-2 23-5 23-6 23-7 23-9 23-8 23-11 23-1...
  • Page 26 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA210WH Model Only) PART NO. Quantity KEY NO. DESCRIPTION KFA210WH Fuel Tank Assmebly 2151-0029-00 Fuel Drain-Bolt 4329-0072-00 Fuel Gauge 2156-0052-00 Fuel Filter Assmbly 2155-0001-00 Fuel Cap 2151-0041-00 Cord Bushing 3712-0013-00 Power Cord 3980-0177-00 Shell Lower...
  • Page 27 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA210WH Model Only) PART NO. Quantity KEY NO. DESCRIPTION KFA210WH 23-15 Output Filter See SP-KFA1005 23-16 End Filter Cover 3221-0076-00 23-17 Ball See SP-KFA1010 23-18 Spring See SP-KFA1010 23-19 Adjusting Screw See SP-KFA1010 23-20 Bolt Flange...
  • Page 28 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (WHEELS AND HANDLE) 1) KFA50WH/75WH MODELS PART NO. Quantity KEY NO. DESCRIPTION KFA50WH KFA75WH Handle 3231-0073-00 3231-0073-00 Hardware Kit HW-KFA1001 HW-KFA1001 2) KFA125/170/210WH MODELS PART NO. Quantity KEY NO. DESCRIPTION KFA125WH KFA170/210WH Front Handle...
  • Page 30 GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302 Tel: (877) 447-4768 www.ghpgroupinc.com GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302...

This manual is also suitable for:

Kfa50whKfa75whKfa125whKfa170whKfa210wh

Table of Contents