Dyna-Glo DELUX KFA50DGDR User Manual

Dyna-Glo DELUX KFA50DGDR User Manual

Kerosene portable forced air heaters

Advertisement

Quick Links

INDOOR/OUTDOOR PRODUCTS
KEROSENE PORTABLE
FORCED AIR HEATERS
"USER'S MANUAL AND
OPERATING INSTRUCTIONS"
MODEL :
KFA50DGDR, KFA80DGDR
carefully. This USER'S MANUAL has been designed to instruct you as to
the proper manner in which to assemble, maintain, store, and most
Please keep this manual for future reference.
CONSUMER : Retain this manual for future reference.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:30 a.m. - 4:30 pm CST, Monday - Friday.
or email us at customerservice@ghpgroupinc.com
MODEL :
KFA135DGDR, KFA180DGDR,
KFA220DGDR
COMPLIES WITH UL733 AND
ANSI A10.10-1998 CAN/CSA/
B140.0-03 AND CSA
B140.8-1967
IMKFADG-ODT

Advertisement

Table of Contents
loading

Summary of Contents for Dyna-Glo DELUX KFA50DGDR

  • Page 1 INDOOR/OUTDOOR PRODUCTS KEROSENE PORTABLE FORCED AIR HEATERS “USER’S MANUAL AND OPERATING INSTRUCTIONS” COMPLIES WITH UL733 AND ANSI A10.10-1998 CAN/CSA/ B140.0-03 AND CSA B140.8-1967 MODEL : MODEL : KFA50DGDR, KFA80DGDR KFA135DGDR, KFA180DGDR, KFA220DGDR carefully. This USER’S MANUAL has been designed to instruct you as to the proper manner in which to assemble, maintain, store, and most Please keep this manual for future reference.
  • Page 2: Precautions - Safety Guide

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! DANGER: IMPROPER USE OF THIS HEATER CAN RESULT IN SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR CARBON MONOXIDE POISONING. WARNINGS: 1. RISK OF INDOOR AIR POLLUTION! • Use this heater only in well ventilated areas. Provide at least a three-square foot (2,800 sq. cm.) opening of fresh outside air for each 100,000 BTU/hr.
  • Page 3: Table Of Contents

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! CONTENTS OF USER’S MANUAL ITEM PAGE # PRECAUTIONS - SAFETY GUIDE ............1. INTRODUCTION ................2. FEATURES ..................3. UNPACKING AND ASSEMBLY ............4. FUEL SELECTION ................5. OVERVIEW OF HEATER DESIGN ........... 6.
  • Page 4 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Front Handle Upper Shell Hot Air Outle t Rear Handle Shell Lower Cord Wrap Fuel Gauge Fuel Cap Side Cover Pressure Gauge Lam p Fan Guard Thermostat Knob Room Temp. Display Power Cord (Piggy Back) Power/Reset Switc h 10”...
  • Page 5: Unpacking And Assembly

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 3. UNPACKING AND ASSEMBLY 1. REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX. (Fig. 4 and 5) NOTE : Save the shipping carton and packing materials for future storage. KFA50DGDR KFA180DGDR KFA135DGDR KFA80DGDR KFA220DGDR...
  • Page 6 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 2. ASSEMBLY Screw For KFA50DGDR/80DGDR Models only Handle Front Guard (Assembly time for this product is 3 minutes) Tools Required Wedged Portion Remove Screws • Medium Phillips Screwdriver. Slit Hole 1) Lift front guard for arrow direction and make Shell Upper hole on the upper housing.
  • Page 7: Fuel Selection

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Screw Cap Nut S Front Handle Rear Handle Hot Air Outlet Cord Wrap Flange Screw Fuel TankFlange Air Inlet Wheel Support Frame Threaded Axle Wheel Wheel Bushing Cap Nut L Figure 7. Assembling Handle, Wheel and Cord wrap CAUTION: DO NOT OPERATE heater without support frame assembled to tank.
  • Page 8: Overview Of Heater Design

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 5. OVERVIEW OF HEATER’S DESIGN Fuel System: This heater is equipped with an electric air pump that forces air through the air line connected to the fuel intake and then through a nozzle in the burner head. When the air passes in front of the fuel intake it causes fuel to rise from the tank and into the burner nozzle.
  • Page 9: Fueling Your Heater

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 6. FUELING YOUR HEATER NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE : FILL THE TANK OUTDOORS. DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED. IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER : manufacturing the heater to burn off outside.
  • Page 10: Long Term Storage Of Your Heater

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Btu Control Switch Room Temp. Display Btu Control Switch Push to"HIGH" Lamp Lamp Push to"LOW" Thermostat Power/Reset Thermostat Power/Reset Relief Valve Switch Control Knob Switch Control Knob (KFA80DGDR MODEL ONLY) KFA50DGDR/80DGDR Models KFA135DGDR/180DGDR/220DGDR Models Fan Guard Figure 8.
  • Page 11: Maintenance

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 9. MAINTENANCE WARNING!! : NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR WHILE HOT! USE ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of third party or other alternate components will void warranty and may cause unsafe operating conditions.
  • Page 12 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! E.) NOZZLE REMOVE DIRT IN NOZZLE AS NEEDED (SEE PAGE 16). Combustion Chamber (For KFA50DGDR/80DGDR/135DGDR/180DGDR Models Only) Screw - Remove upper shell (See page 10). Ignitor Wire - Remove fan blade (See page 10). - Remove fuel and air line hoses from nozzle adaptor.
  • Page 13 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Screw F.) SPARK PLUG CLEAN AND REGAP EVERY 600 HOURS OPERATION OR REPLACE AS NEEDED. (For KFA50DGDR/80DGDR/135DGDR/180DGDR Models Only) Spark Plug - Remove upper shell (See page 10). - Remove fan (See page 10). Ignitor Wire - Remove ignitor wire from spark plug.
  • Page 14 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! H.) FUEL FILTER CLEAN OR REPLACE TWICE A HEATING Fuel Filter SEASON OR AS NEEDED. - Remove side cover screws using medium phillips Fuel Line screwdriver. - Disconnect switch wires from power switch and Switch Wires remove side cover.
  • Page 15: Replacing Fuse

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 10. REPLACING FUSE NOTICE : This heater is fuse protected. If your heater fails to ignite, DO NOT RETURN YOUR HEATER TO THE STORE. Please follow the simple instructions below to inspect and change the fuse. PROCEDURE FOR REPLACING FUSE WARNING : SHOCK HAZARD To prevent personal injury, unplug the power cord before replacing fuse.
  • Page 16: Troubleshooting Guide

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 11. TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE CORRECTIVE ACTION Heater ignites but MAIN PCB 1. Wrong pump pressure. 1. See Pump Pressure Adjustment, assembly shuts heater off after a 2. Dirty Air Output,Air Intake Page 13.
  • Page 17: Wiring Diagram

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 12. WIRING DIAGRAM A) WIRING DIAGRAM (KFA50DGDR Model) CONTROL PCB DISPLAY PCB SPARK PLUG BLACK IGNITOR POWER LAMP (LED) BLACK ORANGE BLACK PUMP WHITE MOTOR CAPACITOR GREEN 15uF/230VAC PW-W/H EARTH PW-BLK BLACK PHOTO CELL BLACK POWER LIMIT...
  • Page 18: Specifications

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 13. SPECIFICATIONS 32.0"(813mm) 11.7"(297mm) KFA50DGDR/80DGDR Models 180DGDR 135DGDR 220DGDR 41.9”(1,063 mm) 47.4”(1,205 mm) 21.5”(547 mm) 23.1”(587 mm) 32.4”(824 mm) 33.5”(850 mm) KFA135DGDR/180DGDR/220DGDR Models MODEL KFA50DGDR KFA80DGDR KFA135DGDR KFA180DGDR KFA220DGDR HIGH 50,000 80,000 135,000 180,000 220,000 BTU/Hr.
  • Page 19: Exploded Parts Drawing

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 14. EXPLODED PARTS DRAWING (KA50DGDR/80DGDR Models Only) NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS. BURNER HEAD ASSEMBLY 20-3 20-8 20-5 20-7 20-2 20-1 20-4 20-6 MOTOR AND PUMP ASSEMBLY 23-2 23-5 23-6...
  • Page 20 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA50DGDR/80DGDR Models Only) PART NO. Quantity KEY NO. DESCRIPTION KFA50DGDR KFA80DGDR Fuel Tank Assmebly 2151-0046-01 2151-0047-01 Fuel Drain-Bolt Fuel Gauge 2156-0046-00 2156-0049-00 Fuel Filter Assmbly 2155-0005-00 2155-0005-00 Fuel Cap 2151-0041-00 2151-0041-00 Power Cord 3980-0274-00...
  • Page 21 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA50DGDR/80DGDR Models Only) PART NO. Quantity KEY NO. DESCRIPTION KFA50DGDR KFA80DGDR 23-13 Lint Filter See SP-KFA1005 See SP-KFA1005 23-14 Bolt Flange 4329-0081-00 4329-0081-00 23-15 Output Filter See SP-KFA1005 See SP-KFA1005 23-16 End Filter Cover 3221-0029-00...
  • Page 22 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 14. EXPLODED PARTS DRAWING (KFA135DGDR/180DGDR Models Only) NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS. BURNER HEAD ASSEMBLY 18-3 18-8 18-5 18-7 18-2 18-1 18-4 18-6 MOTOR AND PUMP ASSEMBLY 21-2 21-5 21-6...
  • Page 23 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA135DGDR/180DGDR Models Only) PART NO. Quantity KEY NO. DESCRIPTION KFA135DGDR KFA180DGDR Fuel Tank Assmebly 2151-0048-01 2151-0049-01 Fuel Drain-Bolt 4329-0072-00 4329-0072-00 Fuel Gauge 2156-0051-00 2156-0051-00 Fuel Filter Assmbly 2155-0001-00 2155-0001-00 Fuel Cap 2151-0041-00 2151-0041-00 Power Cord...
  • Page 24 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA135DGDR/180DGDR Models Only) PART NO. Quantity KEY NO. DESCRIPTION KFA135DGDR KFA180DGDR 21-15 Output Filter See SP-KFA1005 See SP-KFA1005 21-16 End Filter Cover 3221-0076-00 3221-0076-00 21-17 Ball See SP-KFA1010 See SP-KFA1010 21-18 Spring See SP-KFA1010...
  • Page 25 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 14. EXPLODED PARTS DRAWING (KFA220DGDR Model Only) NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS. BURNER HEAD ASSEMBLY 17-8 17-3 17-7 17-1 17-5 17-2 17-4 17-6 MOTOR AND PUMP ASSEMBLY 20-2 20-5 20-6...
  • Page 26 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA220DGDR Model Only) PART NO. Quantity KEY NO. DESCRIPTION KFA220DGDR Fuel Tank Assmebly 2151-0049-01 Fuel Drain-Bolt 4329-0072-00 Fuel Gauge 2156-0052-00 Fuel Filter Assmbly 2155-0001-00 Fuel Cap 2151-0041-00 Power Cord 3980-0275-00 Shell Lower 3111-0504-08 Flange Screw...
  • Page 27 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA220DGDR Model Only) PART NO. Quantity KEY NO. DESCRIPTION KFA220DGDR 20-15 Output Filter See SP-KFA1005 20-16 End Filter Cover 3221-0076-00 20-17 Ball See SP-KFA1010 20-18 Spring See SP-KFA1010 20-19 Adjusting Screw See SP-KFA1010 20-20 Bolt Flange...
  • Page 28: Parts List

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (WHEELS AND HANDLE) 1) KFA50DGDR/80DGDR MODELS PART NO. Quantity KEY NO. DESCRIPTION KFA50DGDR KFA80DGDR Handle 3231-0073-00 3231-0073-00 2) KFA135DGDR/180DGDR/220DGDR MODELS PART NO. Quantity KEY NO. DESCRIPTION KFA135DGDR KFA180DGDR/220DGDR Front Handle 3551-0023-00 3551-0022-00 Rear Handle...
  • Page 29 Warranty LIMITED WARRANTY: This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale.GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group,Inc., within one (1) year of retail purchase.
  • Page 30 WARRANTY REGISTRATION days of date of purchase. You can also register your warranty on the internet at www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records. GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302 Tel: (877) 447-4768 www.ghpgroupinc.com SAVE THIS CARD!

Table of Contents