Overview Of Heater Design - Dyna-Glo KFA80H User's Manual And Operating Instructions

Kerosene portable forced air heaters
Table of Contents

Advertisement

NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
5. OVERVIEW OF HEATER'S DESIGN
Fuel System: This heater is equipped with an electric
air pump that forces air through the air
line connected to the fuel intake and then
through a nozzle in the burner head.
When the air passes in front of the fuel
intake it causes fuel to rise from the tank
and into the burner nozzle. This fuel and
air mixture is then sprayed into the
combustion chamber in a fine mist.
"Sure Fire Ignition" : The electronic ignitor sends voltage to a specially designed spark plug.
The Air System : The heavy duty motor turns a fan that forces air into and around the combustion chamber.
The Safety System :
A. Temperature Limit Control : This heater is equipped with a Temperature Limit Control designed to turn
MODELS
KFA50H
KFA80H
KFA135H
KFA220H
B. Electrical System Protection : This heater's electrical system is protected by a fuse mounted to the PCB
C. Flame-Out Sensor : Utilizes a photocell to monitor the flame in burn chamber during normal operation.
The spark plug ignites the fuel and air mixture described above.
Here the air is heated and then forced out the front of the heater.
off the heater should the internal temperature rise to an unsafe level. If this
device activates and turns your heater off it may require service.
Internal Shut-Off Temp.
Plus/Minus 10 Degrees
assembly that protects it and other electrical components from damage.
If your heater fails to operate check this fuse first and replace as needed.
FUSE TYPE:
It will cause the heater to shut-off should the burner flame extinguish.
176˚F/80˚C
158˚F/70˚C
158˚F/70˚C
194˚F/90˚C
All Models
7
Reset Temperature
Plus/Minus 10 Degrees
122˚F/50˚C
104˚F/40˚C
104˚F/40˚C
140˚F/60˚C
125 volt / 8 amps

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kfa50hKfa135hKfa220h

Table of Contents