Storage - Toro 09830 Operator's Manual

Hydroject injection system for hydroject aerators
Table of Contents

Advertisement

Note:
To help keep the chemical tank clean:
Rinse the tank thoroughly and often.
Mix additive solutions daily.
Don't mix solutions together that may
react and form a precipitate.
Use fresh filtered water when filling
the tank.
Figure 18
1. Chemical Tank
1
2
2. Drain Hose Connector

Storage

1.
Rinse the lower end with fresh soapy water.
2.
Remove the injector from the HydroJect as
follows:
A. Remove the drain hose connector from the
bottom of the chemical tank (Fig. 18).
B. Disconnect the water hoses from the
injector.
C. Remove the hairpin cotters and remove the
injector from the support bracket (Fig. 19).
3.
Rotate the injector until all water is drained.
4.
Remove the interlock pins and disassemble the
plunger and cylinder assemblies (Fig. 19).
5.
Clean the plunger and cylinder assemblies
(Fig. 19).
6.
Reassemble the plunger and cylinder assemblies
(Fig. 19).
7.
Reinstall the injector to the HydroJect .
1
3
Figure 19
1. Hairpin Cotter (2)
2. Interlock Pin (4)
Maintenance
4
2
3. Plunger Assembly
4. Cylinder Assembly
21