Alcove Clearance To Combustible - Napoleon STARfire Series Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

framing
EN
4.2.2 alcove clearance to combustible enclosure
note:
When framing with an alcove, the enclosure height must be 72" (1829mm), not 70" (1778mm).
56 3/4"
1441mm
CEILING
72"
1829mm
ENCLOSURE
HEIGHT
* See venting section.
important:
The firestop assembly provided must be used when the vent pipes pass through any combustible wall, floor, or
ceiling.
30
W415-2372 / B / 12.09.20
COMBUSTIBLE
STEEL STUD
6"
FRAMING
152mm
MAX
NON-COMBUSTIBLE
MATERIAL
16 1/4"
413mm
49"
1245mm
32 3/4"
832mm
INSULATED
STEEL STUD
INSULATED
SLEEVE
2"
51mm
1"
25mm
2"
51mm
0" IF NON-COMBUSTIBLE
FINISHING MATERIAL
IS USED SUCH AS
BRICK AND STONE.
1"
25mm
FIRESTOP
ASSEMBLY
52 7/16"
1332mm
MINIMUM
PLUS RISE *
2"
51mm
0" IF NON-COMBUSTIBLE
FINISHING MATERIAL
IS USED SUCH AS
BRICK AND STONE.