8. CHARGING INSTRUCTIONS

1. When the charging process is interrupted, press the ON/OFF button, and then
restart the charger.
2. To turn off the charger by pressing and holding the ON/OFF button for 3 seconds.
3. To restart the charger by pressing and holding the ON/OFF button for 3 seconds.
STEP 1 – CHECK THE ELECTROLYTE LEVEL
Prior to charging the battery, remove the vent caps and check the electrolyte
level (not required on sealed & maintenance free batteries). The electrolyte
should be 6mm (1/4") above the battery's plates. If low, top up with distilled
water to the correct level and refit the vent caps.
STEP 2A – CONNECTION OUT OF THE VEHICLE
Connect the RED lead (battery clip) from the charger to the Positive (+)
battery post.
Connect the BLACK lead (battery clip) from the charger to the Negative (-)
battery post.
BLACK
RED
F A N
Connection out of vehicle
STEP 2B – CONNECTION IN VEHICLE
Determine if the vehicle is Positively (+) or Negatively (-) earthed. Negatively
earthed vehicles have a cable (usually black) from the Negative battery terminal
'
to the vehicle
s chassis.