paco LBC1205 Instruction Manual page 8

Table of Contents

Advertisement

STAGE LAMP: illuminates and flashes when 8-stage charging process.
STAGE LAMP: illuminates solid when fully charged.
POWER ON LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT
The charger has entered the energy save mode. This happens if the
charger isn't connected to the battery in 2 minutes.
FAULT LAMP STEADY LIGHT
If the fault lamp is lit solid , check the following:
Has charging been interrupted in STEP 1, 2, or 4?
Restart the charger by pressing the ON/OFF-button. If charging is still being
interrupted, the battery.
STEP 1: ...can not accept charge and may need to be replaced.
STEP 2: ... battery is faulty and may need to be replaced. (Bulk charging has
timed out and stopped after 10 hours.)
STEP 4: ...can not keep charge and may need to be replaced.
FAULT LAMP FLASHING LIGHT
★ Charger's internal temperature is higher than 65