8-stage automatic battery charger

Advertisement

8-STAGE AUTOMATIC
BATTERY CHARGER
MCU CONTROLLED & HIGH FREQUENCY SWITCHMODE
P/No. MFC1205L MFC1207L MFC1210L MFC1212L
MFC1215L
MFC1220L MFC2405L MFC2410L
Instruction Manual
Please read user manual carefully before use.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MFC1205L and is the answer not in the manual?

Questions and answers

Summary of Contents for paco MFC1205L

  • Page 1 8-STAGE AUTOMATIC BATTERY CHARGER MCU CONTROLLED & HIGH FREQUENCY SWITCHMODE P/No. MFC1205L MFC1207L MFC1210L MFC1212L MFC1215L MFC1220L MFC2405L MFC2410L Instruction Manual Please read user manual carefully before use.
  • Page 2 1. WARNING Explosive gases may escape from the battery during charging. Prevent flames and sparks. Provide adequate ventilation. Before charging, read the instructions. For indoor use. Do not expose to rai n . For charging 12V/24V Lithium-ion with LiFePO batteries and Lead Acid batteries ONLY.
  • Page 3: Step 1 Soft Start

    The Lithium battery mode 8 stages are: Soft Start Bulk Absorption Analyse Completion Maximization Float and Maintain. STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 STEP 8 INCREASES CHARGING WITH CHARGING WITH TESTS IF THE BATTERY FINAL CHARGE FINAL CHARGE FLOAT CHARGE...
  • Page 4 Bulk mode for the charging cycle. The start phase continues until the battery's terminal voltage has risen above the set limit, at which point the charger switches to bulk charging. If the terminal voltage has not passed the voltage limit within the time limit, the charger switches to fault mode (Step 2 lamp solid) and discontinues the charging.
  • Page 5 100%~20% at 100%~20% at 100%~20% *SMALL - This mode only for MFC1205L *NIGHT - This mode is equal to NORMAL, but with reduced current Desulphation The Desulphation stage may break down sulphation that occurs in batteries that have been left flat for extended periods of time, returning them back to full charge.
  • Page 6 terminal voltage has risen above the set limit, at which point the charger switches to bulk charging. If the terminal voltage has not passed the voltage limit within the time limit, the charger switches to fault mode (Step 3 lamp solid) and discontinues the charging.
  • Page 7 3.SWITCHMODE TECHNOLOGY Using the latest technology in battery chargers, switch mode chargers convert 110V/220-240V AC power to 12V/24V DC power using electronic components unlike traditional battery chargers that rely on heavy transformers. This allows the charger to be light weight and compact without sacrificing on performance. 4.PROTECTIVE FEATURES POLARITY PROTECTION Prevents the output leads from sparking due to accidental reverse connection...
  • Page 8: Product Overview

    5. PRODUCT OVERVIEW The 8-stage automatic charging consists of the following components: 1.Mode button 2.Stage lamp status display indicates power, charging and fully charged. 3.Power lamp 4.Fault Led 5.Output voltage meter 6.Charging mode 7.DC leads. 8.Power Cord 9.Thermostatically controlled cooling fan 10.Ground terminal 11.Mounting flange.
  • Page 9: Charge Status Indicator

    6. CHARGE STATUS INDICATOR The LITHIUM BATTERY CHARGING and STAGE LAMP will illuminate and flash in various patterns to indicate the different stages of charging. See below for flash / steady patterns. Power on Stage Fault lamp lamp lamp display Power Off Power On 1.
  • Page 10 STAGE LAMP: illuminates and flashes when 8-stage charging process. STAGE LAMP: illuminates solid when fully charged. POWER ON LAMP If the power lamp is lit with a: 1. STEADY LIGHT The mains cable is connected to the wall socket. 2. FLASHING LIGHT The charger has entered the energy save mode.
  • Page 11 The Lead Acid battery CHARGING and STAGE LAMP will illuminate and flash in various patterns to indicate the different stages of charging. See below for flash / steady patterns. Power on Fault Stage display lamp lamp lamp Power Off Power On Power On 1.
  • Page 12 STAGE LAMP: illuminates and flashes when 8-stage charging process. STAGE LAMP: illuminates solid when fully charged. POWER ON LAMP If the power lamp is lit with a: 1. STEADY LIGHT The mains cable is connected to the wall socket. 2. FLASHING LIGHT The charger has entered the energy save mode.
  • Page 13 7. SPECIFICATIONS P/No. MFC 1205L MFC 1207L MFC 1210L Charger Type 8-Stage automatic Input Voltage 220-240V , 50/60Hz 110V , 60Hz Input Power 154W 215W 307W Output Voltage 12V DC 12V DC 12V DC Output Current Minimum Start Voltage Lead Acid: 2.0V Lithium: 1.0V Back Drain Current Fuse Rating T3.15A, 250V AC...
  • Page 14 8. SPECIFICATIONS P/No. MFC 1212L MFC 1215L MFC 1220L Charger Type 8-Stage automatic Input Voltage 220-240V , 50/60Hz 110V , 60Hz Input Power 332W 415W 554W Output Voltage 12V DC 12V DC 12V DC Output Current Minimum Start Voltage Lead Acid: 2.0V Lithium: 1.0V Back Drain T3.15A, 250V AC T5A, 250V AC...
  • Page 15 9. SPECIFICATIONS P/No. MFC 2405L MFC 2410L Charger Type 8-Stage automatic Input Voltage 220-240V , 50/60Hz 110V , 60Hz Input Power 296W 547W Output Voltage 24V DC 24V DC Output Current Minimum Start Voltage Lead Acid: 4.0V Lithium: 2.0V Back Drain Current Fuse Rating T3.15A, 250V AC T5A, 250V AC...
  • Page 16: Charging Instructions

    10. CHARGING INSTRUCTIONS 1. Settings are made by pressing the MODE-button. After about two seconds the charger activates the selected program. The selected program will be restarted next time the charger is connected. 2. To turn off the charger by pressing and holding the Mode button for 3 seconds. 3.
  • Page 17 STEP 2A CONNECTION OUT OF THE VEHICLE Connect the RED lead (battery clip) from the charger to the Positive (+) battery post. Connect the BLACK lead (battery clip) from the charger to the Negative (-) battery post. BLACK F A N Connection out of vehicle STEP 2B CONNECTION IN VEHICLE...
  • Page 18 b)Positively earthed Connect the BLACK lead (battery clip) from the charger to the Negative (-) battery terminal. Connect the RED lead (battery clip) from the charger to the vehicle's chassis away from the fuel line or moving parts. BLACK F A N Connection in vehicle (positively earthed) c)Chassis earthing...
  • Page 19: Mounting Instructions

    STEP 4 CHARGING During the charge process, the CHARGING and STAGE LAMP will flash various patterns. This is normal and ind icates the various charge stages. Refer to "How can I know what stage the battery charger is in" in the FAQ sectio n, page 22. When the STAGE LAMP remains on, this is known as the floa t stage and the charger can be left connected to the battery wi t hout over charging.
  • Page 20 12. PERMANENT WIRING TO BATTERY It is possible to hard wire the DC charging leads to the battery for permanent installations. You will need 2 x ring terminals, an inline fuse holder and a fuse with a rating equal to or more than twice of the chargers output. (See below) 5A = 10 Amp fuse 7A = 14 Amp fuse 10A = 20 Amp fuse 12A = 24 Amp fuse 15A = 30 Amp fuse 20A = 40 Amp fuse...
  • Page 21 If the charger is used in a Permanent / Hard Wired application and the vehicle will not be used for some time, it is best to leave the charger connected to mains power (turned "On") so that it can maintain the battery fully charged. Ensure any modification to the 110V/220-240V AC mains lead is carried out by a qualified person and that connection to supply mains is in accordance with National wiring rules.
  • Page 22: Fault Codes

    14. FAULT CODES There are error codes that may be displayed. These will be displayed in the following way: Power Stage Fault Remedy Error Code Cause lamp lamp lamp Check clips are Polarity Lithium: Short circuit not touching each Reverse or reverse other.
  • Page 23: Frequently Asked Questions

    15. FREQUENTLY ASKED QUESTIONS Q. How do I know if the battery is charged? A. The charger's FULLY STAGE LAMP will illuminate (solid). Alternatively use a Battery Hydrometer A reading of 1.250 or more in each cell indicates a fully charged battery. Q.
  • Page 24 CAUTION ALWAYS PLACE THE BATTERY CHARGER IN AN ENVIRONMENT WHICH IS: A. WELL VENTILATED. B. NOT EXPOSED TO DIRECT SUNLIGHT OR HEAT SOURCE. C. OUT OF REACH FROM CHILDREN. D. AWAY FROM WATER / MOISTURE, OIL OR GREASE. E. AWAY FROM ANY FLAMMABLE SUBSTANCE. F.