Menu Descriptions
Definitions
Mode
Mode changes the operation of the heater between heat
mode and ventilation mode. Status indicator lights will
illuminate red for heat mode and blue for ventilation mode when
the selected mode is active.
Note: Refer to Status Indicator Light description on page 6
for additional Status Indicator explanation.
Language
Language changes between English, Spanish, and French.
Temp Unit
Temp Unit changes between Fahrenheit and Celsius units of
measure.
Options
Advanced level adjustments; see below.
 Duration
Duration allows for the selection of continuous heater operation or
timed operation (30 minutes – 14 hours in 30 minute increments).
IMPORTANT: Timed duration is not to be mistaken for Timer
functionality. The duration times above are used when turning the
heater on manually. I.e. set the heater duration for 8 hours before
heading to bed.
Note: If timed operation is selected 10 hours is default.
LVD "Low Voltage Disconnect" allows the user to set the battery
 LVD
voltage level at which the Webasto SmarTemp Control 2.0 will shut
down the heater. A warning (LED and message) will appear after 8
minutes of low voltage. The warning will remain on for 2 minutes
before the heater is shut off. If battery voltage is equal to or less
than the threshold selected +0.1v, the heater will not start. I.e. if
an 11.5v threshold is selected the heater cannot be started until B+
has reached 11.7v.
12 volt - Range between 11v – 12.5v
24 volt - Range between 21v – 25.5v
 Password
A password can be set to prevent access to the advanced
"Options" menu. Enter a 4 digit code passcode to begin
securing the "Options" menu.
Note: This is typically used in fleet vehicle applications.
 PM
If the heater has not run 30 days, the preventive maintenance
Reminder
(PM) reminder will alert the operator with a message to run the
heater for 20 minutes. The indicator lights will flash red as a visual
reminder.
The operator will have the ability to Start the 20 minute
maintenance cycle or delay it via a "Snooze" option. When
Snooze is selected the PM reminder will postpone until 12:00PM
the following day.
Scan for interactive demo
Default
Heat Mode
English
Fahrenheit
Continuous
11.4 V
24.02 V
OFF
ON