Control Panel Functions; On/Off Start Switch; Usb Outlet; Indicator Lights - Ford FG4500iS Operator's Manual

Inverter gasoline generator
Table of Contents

Advertisement

FUEL VALVE
"OFF" position, the fuel valve is switched off and the engine will not run.
When the Start Switch is in the "ON" position the fuel valve is switched on and the
engine can run.

USB Outlet

The Generator offers convenient (5V DC 1.0/2.1A) USB outlet to allow charging of
USB devices like Tabelets, MP3 players, GPS, Digital Cameras and other USB
chargable devices.
Oil Warning Indicator Light
When the oil falls below the minimum level, the oil warning indicator
light comes on and the engine stops automatically. The engine will not
start until the proper amount of oil is in the crank case.
Note: If the oil warning indicator light does not come on and the engine stalls, turn
the fuel valve to "ON" and pull the recoil starter.
Engine Overload Indicator Light
If the engine overload indicator light comes on, the generator s wattage / amperage
capacity has been exceeded by connected electrical devices or by a power surge.
When this occurs, the green AC Pilot Indicator Light will go off. The engine will
continue to run, (but the red Engine Overload Indicator Light will stay on and power
will no longer be supplied to connected electronic devices.)
Note: The engine overload indicator light may turn on for a few seconds when
attaching a load due to a power surge. This is normal.

CONTROL PANEL FUNCTIONS

8
USB
OUTPUT
OVERLOAD
OUTPUT
OVERLOAD