3.2.7 - Level 7 - SetP (Programmable Setpoint)

The DCY-2057 Controller can run a program which generates, repeatedly, up
to ten setpoint values.
The setpoint values, the time taken to reach these values and the number of
times this setpoint sequence should be repeated are parameters selected by the user
within Configuration level 7.
Figure 28 shows an illustration of a wave form obtained from the setpoints
programmed by the user. Note that the first setpoint (SP-1) is reached from the local
setpoint and that after running the programmable setpoint the value to be used for
the local setpoint will be the last value obtained by the programmable setpoint.
DCY - 2057 Pressure Controller
Fig. 28 - Evolution of the programmable setpoint
Maintenance