The adjustable parameter ranges shown on figure 17 are given below.
Mnemonic
LIM LOW
percentage of output full
scale (20 mA, 5V or
10V) defining the lowest
output signal. The output
saturates in this value.
LIM HIGH
percentage of output full
scale (20 mA, 5V or
10V) defining the highest
output signal. The output
saturates in this value.
RELAY
time associated to relay
cycle (PWM period) for
outputs 1 and 2.
The control output will only be enabled after the output type is selected
with the values are assigned to the related parameters.
DCY - 2057 Pressure Controller
Fig. 17 - OUTPUT Level Options
Parameter
(1) FOLLOWS THE SAME OPTIONS FOR OUTPUT 2
(2) SAME AS 5V OPTION
Adjustable
Factory
Span
Value
0.0 to 100.0
0.0 to
100.0
105.0%
1.0 to 120.0
Units
0.0
%
%
10.0
s
Operation
Page 31