Lipo/Liio/Life/Lihv/Lto/Nizn/User Discharge Advanced Setup; Lipo/Liio/Life/Lihv/Lto/Nizn/User Discharge Safety Setup; Lipo/Liio/Life/Lihv/Lto/Nizn/User Cycle Setup; Lipo/Liio/Life/Lihv/Lto/User Only Balance Feature - iCharger 456DUO User Manual

Table of Contents

Advertisement

1. For example, a 12V/60W bulb as the load of To Channel, it should set Voltage Limit =12V;Current Limit=60/12=5A.
2. When the battery as the load of To Channel, Voltage Limit and Current Limit are not settable,see details on Channel
Regenerative Mode .
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Discharge Advanced Setup
Click "Advanced" to enter DISCHARGE ADVANCED SETUP interface.
1. Tick Extra Discharge Enable to activate discharge enable, see more details on Lithium Battery Extra Discharge
Mode.
2. Tick Balance Enable to activate balance discharge; when discharge enters the CV phase, it starts to balance the cell
voltages.
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Discharge Safety Setup
Click "Safety" to enter DISCHARGE SAFETY SETUP interface.
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Cycle Setup
Select Program→Cycle to enter CYCLE SETUP interface.
LiPo/LiIo/LiFe/LiHV/LTO/User Only Balance Feature
Select Program→Balance Only to enter Balance Only setup interface.
Dual Balance Charger/Discharger/DC Power
Channel Join:
Resistance or bulbs (default)
Charging battery
Voltage Limit:
2V-32V; default: 12V
Current Limit:
0.05A-45A; default: 1A
20℃-80℃; default: 45℃
Cut-Temp:
Max Capacity:
50%-200%; default: 90%
Safety Timer:
1Min-9999Min; default: off
Cycle Mode:
CHG
CHG
CHG
Cycle Count:
1-9999; default: 3
Delay Time:
0Min-9999Min; default: 3Min
- 20 -
DCHG(default),DCHG
DCHG CHG, DCHG
CHG DCHG,
DCHG STO, DCHG
CHG STO
456DUO
CHG