SPECIFICATIONS

T3/T3M/T3R Thermostat
:   Fuzzy Logic
Control form
:   From 0 °C to 50 °C
Room
temperature
display range
:   T3/T3M: 136 x 97 x 26 mm
Dimensions
T3R (Wireless) 136 x 98 x 62 mm
(w x h x d)
:   24 hour or 12 hour AM/PM format
Time display
:   +/‐ 10mins per year
Time keeping
accuracy
:   5+2 or daily schedule with 4 daily time and 
Program
temperature level changes
:   Program – 10 minute steps
Time setting
resolution
:   10k(@25 °C) NTC thermistor
Sensing
element 
:   Program: 5 to 35 °C
Temperature 
OFF         : 5 °C
Setting range
:   Powered by 2 x AA batteries 
Power
:   T3(wired) and T3M (Opentherm) terminal 
Wiring
block capable of accepting wired up to 1.5 
2
mm
RF communication
RF operation band 
:   ISM (868.0‐868.6) MHz, 1% duty cycle
Max, power
:   25mW
Protocol
:   Encrypted
Comm. Range
:   30m in residential building 
environment
Comm. Technology
:   short, high rate transmissions to 
minimise air time and avoid collisions
Receiver class
:   RX Cat 2 (ETSI EN300 220‐1 version
R.E.D.
1.3.1)
T3 PROGRAMMABLE THERMOSTAT 
Receiver box
:   230VAC
Power
:   230V~, 50..60Hz, 0.5A to 5A resistence
Electrical rating
0.5A to 3A inductive (0.6 pf)
24V~, 50..60Hz, 0.5A to 5A resistence
0.5A to 3A inductive (0.6 pf
:   Selectable by application (see installer 
Cycle rate      
set up
Wiring
:   Terminal block capable of accepting 
wires up to 1.5 mm
:   From back via large wall box opening.
Wire access
From bottom with cable clamps.
Mains wiring – left
Low voltage wiring ‐ right
:   110 x 110 x 40 mm
Dimensions
(w x h x d)
:   30
IP class
Environmental and standards
:   0 to 40 °C
Operating 
temperature range
:   ‐20 to 55 °C
Shipping and storage
temperature
:   10 to 90% rh, non‐ condensing
Humidity range
:   2014/30/EU
EMC
LVD
:   2014/35/EU
R&TTE
:   1995/5/EC
:   From back via large wall box opening.
Wire access
:   Class IV (+2%), (EU) 811/2013 (T4)
ErP
Class V (+3%), (EU) 811/2013 (T4R)
Class VI (+4%), (EU) 811/2013 (T4M)
Honeywell, declares that this thermostat is in compliance 
with the essential requirements and other relevant 
provisions of Directive 2014/53/EU