4.3.1. Copying function "copy"

The data stored in a memory can be copied to another memory selected from among four
memories (the inverter's memory and Remote Keypad memories A, B, and C). Remote Keypad can
not be used to copy parameters from one inverter to another inverter of a different series.
N.B.: To copy the data to the inverter's memory, do it when the inverter has stopped. If you copy
the data to the inverter while the inverter is running, some of the parameters fail to be copied.
Operating procedure
Key
LED indication
"copy"
ENT
"copy"
"in"
"a"
SFT
"c"
"in"
ENT
"in"
"in-a"
"in-a"
"in-c"
SFT
"a-in"
"a-c"
"a-in"
"in-a"
ENT
"f_ _ _"
"c0mp"
"_ _ _ _"
(4 digits)
ENT
"_ _ _ _"
- If the [ESC] key is pressed, Remote Keypad returns to previous status (except when executing).
- When the memory protection function is actuated, Remote Keypad inhibits copying data with " prot " appearing in
the display window.
- If there is no data in memory A of Remote Keypad upon selection as data to copy from, the display shows " err.a "
which means copying data is impossible. (When the memory B or C is selected in the same condition, " err.b " or
" err.c " appears in the display window
- In " a-in" ," b-in" and " c-in" , when the data of the inverter increases by the upgrade, the data not included
in memory A, B, and C is not changed.
< Selecting a desired function >
Select " c0py " (copying function) with the [SFT] key.
(" c0py " automatically appears just after starting up.)
< Entering the selected function >
After selecting " c0py " with the [SFT] key, press the [ENT] key. " in " (selecting
"in"
inverter memory) appears in the display window.
< Selecting a memory to copy its data >
Select a memory to copy its data with the [SFT] key.
Each time the [SFT] key is pressed, the display changes as follow:
"b"
" in "
" a "
" b "
" c "
and to " in " again in this order.
< Entering the memory to copy its data >
After selecting the memory to copy from, press the [ENT] key. Example: select
" in ", press [ENT] key, and " in-a " appears in the display window.
< Selecting a memory to transcribe copied data >
Select a memory to transcribe copied data with the [SFT] key.
Each time the [SFT] key is pressed, the display changes as follow
"in-b"
" in-a " (copying data from inverter memory to memory A)
"in-a"
" in-b " (copying data from inverter memory to memory B)
"a-b"
" in-c " (copying data from inverter memory to memory C)
and to " in-a " again in this order.
If the memory A, B, or C is selected as to copy data from, the display changes
accordingly (example shown in parentheses for memory A).
< Executing copy function >
After selecting the memory to copy to (Example: " in-a " select memory A as to
copy to), press the [ENT] key, and start copying. Then the display shows " f _ _
_". This is the parameter title of the parameter being copied now. If Remote
Keypad is unable to copy the selected parameter, the display shows the parameter
title flashing in the display window. To continue copying, press [ENT] key.
< Completion of copying function >
After completing the copy operation, " c0mp " begins to flash to indicate that
Remote Keypad is comparing two sets of parameters. (Refer to "comparing
function" in section 4.3.3). When the comparison is end, it displays CRC code "_
"end"
_ _ _" (4 digits in hexadecimal number) of memory data for error detection after
displaying " end ". If the parameters are different, the comparison interrupts and
the parameter title number flashes on display. To continue comparison for next
parameter, press [ENT] key. When the comparison is end, the CRC codes of
original and copied memory data for error detection flash alternately after
displaying " end ".
The CRC code "_ _ _ _" (4 digits in hexadecimal number) changes depending on
the data condition.
< Ending copying >
"copy"
Press the [ENT] key and the indication in the display window returns to
" copy ".
Key operation and description
(selecting inverter memory)
(selecting memory A)
(Selecting memory B)
(selecting memory C)
10