4.3.1. Copying function "copy"

The data stored in a memory can be copied to another memory selected from among four memories
(the inverter's memory and Remote Keypad memories A, B, and C). Remote Keypad can not be
used to copy parameters from one inverter to another inverter of a different series.
N.B.: To copy the data to the inverter's memory, do it when the inverter has stopped. If you copy the
data to the inverter while the inverter is running, some of the parameters fail to be copied.
Operating procedure
Key
LED indication
⎯⎯⎯⎯
"copy"
ENT
"in"
SFT
"in"
"in"
ENT
"in-a"
"in-c"
SFT
"a-in"
"a-c"
"in-a"
ENT
"c0mp"
⎯⎯⎯⎯
"_ _ _ _" (4 digits)
"_ _ _ _"
ENT
- If the [ESC] key is pressed, Remote Keypad returns to previous status (except when executing).
- When the memory protection function is actuated, Remote Keypad inhibits copying data with "prot" appearing
in the display window.
- If there is no data in memory A of Remote Keypad upon selection as data to copy from, the display shows
"err.a" which means copying data is impossible. (When the memory B or C is selected in the same condition,
"err.b" or "err.c" appears in the display window.)
< Selecting a desired function >
"copy"
Select "c0py" (copying function) with the [SFT] key.
("c0py" automatically appears just after starting up.)
< Entering the selected function >
"in"
After selecting "c0py" with the [SFT] key, press the [ENT] key.
"in" (selecting inverter memory) appears in the display window.
< Selecting a memory to copy its data >
Select a memory to copy its data with the [SFT] key.
Each time the [SFT] key is pressed, the display changes as follow:
"a"
"b"
"c"
and to "in" again in this order.
< Entering the memory to copy its data >
After selecting the memory to copy from, press the [ENT] key.
"in-a"
Example: select "in", press [ENT] key, and "in-a" appears in
the display window.
< Selecting a memory to transcribe copied data >
"in-b"
Select a memory to transcribe copied data with the [SFT] key.
Each time the [SFT] key is pressed, the display changes as follow
"in-a"
"a-b"
and to "in
If the memory A, B, or C is selected as to copy data from, the
"a-in"
display changes accordingly (example shown in parentheses for
memory A).
< Executing copy function >
After selecting the memory to copy to (Example:
memory A as to copy to), press the [ENT] key, and start copying.
"f_ _ _"
Then the display shows "f_ _ _". This is the parameter title of the
parameter being copied now. If Remote Keypad is unable to copy
the selected parameter, the display shows the parameter title flashing
in the display window. To continue copying, press [ENT] key.
< Completion of copying function >
After completing the copy operation, "c0mp" begins to flash to
"end"
indicate that Remote Keypad is comparing two sets of parameters.
(Refer to "comparing function" in section 4.3.3). With completion of
data comparison, "end" appears in the display window followed
by "_ _ _ _" which indicates the CRC code (calculated from the
copied data). The CRC code value changes depending on the
condition of the data copied from the inverter.
< Ending copying >
"copy"
Press the [ENT] key and the indication in the display window
returns to "copy".
Key operation and description
"in" (selecting inverter memory)
" a"
(selecting memory A)
" b"
(Selecting memory B)
" c"
(selecting memory C)
"in
-
a" (copying data from inverter memory to memory A)
-
"in
b" (copying data from inverter memory to memory B)
-
"in
c" (copying data from inverter memory to memory C)
-
a" again in this order.