Download Print this page
Unitronics UniStream US5-B5-B1 User Manual

Unitronics UniStream US5-B5-B1 User Manual

Built-in

Advertisement

Quick Links

®
UniStream
Built-in
This guide provides basic installation information for specific UniStream
Technical specifications may be downloaded from the Unitronics website.
General Features
Unitronics' UniStream
a built-in CPU, an HMI panel, and built-in I/Os.
The series is available in two versions: UniStream Built-in and UniStream Built-in Pro.
Note that a model number that includes:
B5/C5 refers to UniStream Built-in
B10/C10 refers to UniStream Built-in Pro. These models offer additional features, detailed
below.
HMI
Power
Features
I/O
Options
COM
Options
COM
Protocols
Programming
Software
Unitronics
®
Built-in series are PLC+HMI All-in-One programmable controllers that comprise
▪ Resistive Color Touch-screens
▪ Rich graphic library for HMI design
▪ Built-in Trends and Gauges, auto-tuned PID, data tables, data sampling, and Recipes
▪ UniApps™: Access & edit data, monitor, troubleshoot & debug and more – via HMI or remotely via
VNC
▪ Security: Multi-level password protection
▪ Alarms: Built-in system, ANSI/ISA standards
▪ Built-in I/O configuration, varies according to model
▪ Local I/O via UAG-CX series I/O expansion adapters and standard UniStream Uni-I/O™ modules
▪ Remote I/O using UniStream Remote I/O or via EX-RC1
▪ Built-in ports: 1 Ethernet, 1 USB host, 1 Mini-B USB device port
▪ Serial and CANbus ports may be added via UAC-CX modules
▪ Fieldbus: CANopen, CAN Layer2, MODBUS, EtherNetIP and more. Implement any serial
RS232/485, TCP/IP, or CANbus third-party protocols via Message Composer
▪ Advanced: SNMP Agent/Trap, e-mail, SMS, modems, GPRS/GSM, VNC Client, FTP Server/Client
All-in-One software for hardware configuration, communications, and HMI /PLC
applications, available as a free download from Unitronics.
User Guide
US5-B5-B1, US5-B10-B1, US5-B5-TR22,
US5-B10-TR22, US5-B5-T24, US5-B10-T24,
US5-C5-B1, US5-C10-B1, US5-C5-TR22,
US5-C10-TR22, US5-C5-T24, US5-C10-T24
US7-B5-B1, US7-B10-B1, US7-B5-TR22,
US7-B10-TR22, US7-B5-T24, US7-B10-T24,
US7-C5-B1, US7-C10-B1, US7-C5-TR22,
US7-C10-TR22, US7-C5-T24, US7-C10-T24
US10-B5-B1, US10-B10-B1, US10-B5-TR22,
US10-B10-TR22, US10-B5-T24, US10-B10-T24,
US10-C5-B1, US10-C10-B1, US10-C5-TR22,
US10-C10-TR22, US10-C5-T24, US10-C10-T24
®
models with built-in I/O.
1

Advertisement

loading

Summary of Contents for Unitronics UniStream US5-B5-B1

  • Page 1 US10-C10-TR22, US10-C5-T24, US10-C10-T24 This guide provides basic installation information for specific UniStream ® models with built-in I/O. Technical specifications may be downloaded from the Unitronics website. General Features Unitronics’ UniStream ® Built-in series are PLC+HMI All-in-One programmable controllers that comprise a built-in CPU, an HMI panel, and built-in I/Os.
  • Page 2 ▪ All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. ▪ Please dispose of this product according to local and national standards and regulations.
  • Page 3 Class I, Division 2, Groups A, B, C and D These Release Notes relate to all Unitronics products that bear the UL symbols used to mark products that have been approved for use in hazardous locations, Class I, Division 2, Groups A, B, C and D.
  • Page 4 2, Groups A, B, C et D. Cette note fait référence à tous les produits Unitronics portant le symbole UL - produits qui ont été certifiés pour une utilisation dans des endroits dangereux, Classe I, Division 2, Groupes A, B, C et D.
  • Page 5 Installation Space Considerations Allocate space for: ▪ the controller ▪ any modules that will be installed ▪ access to ports, jacks, and the microSD card slot For exact dimensions, please refer to the Mechanical Dimensions shown below. Unitronics...
  • Page 6 User Guide Mechanical Dimensions UniStream 5” UniStream 7" Unitronics...
  • Page 7 When properly mounted, the panel is squarely situated in the panel cut-out as shown below. ▪ Do not apply torque exceeding 0.35 N·m (3.1 in-lb) of torque to tighten the bracket Caution screws. Using excessive force to tighten the screw can damage this product. UniStream 5” Unitronics...
  • Page 8 First Use The battery is protected by a removable cover on the side of the controller. The battery is supplied installed inside the unit, with a plastic tab preventing contact which must be removed by the user. Unitronics...
  • Page 9 ▪ Use over-current protection, such as a fuse or circuit breaker, to avoid excessive currents into the power supply connection point. ▪ Unused points should not be connected (unless otherwise specified). Ignoring this directive may damage the device. ▪ Double-check all wiring before turning on the power supply. Unitronics...
  • Page 10 ➢ Keep shield connections as short as possible. ➢ Ensure shield continuity when extending shielded cables. For detailed information, refer to the document System Wiring Guidelines, located in the Technical Library in the Unitronics’ website. Wiring the Power Supply The controller requires an external power supply.
  • Page 11 All 10 digital inputs share the common point CM0. The digital inputs may be wired together as sink or source. Input wiring, sink Input wiring, source Use sink input wiring to connect a sourcing (pnp) device. Use source input wiring to connect a sinking (npn) device. Unitronics...
  • Page 12 ▪ The mode is determined by the hardware configuration within the software application. ▪ Note that if, for example, you wire the input to current, you must also set it to current in the software application. Voltage Differential Single-ended Current 2-wire 3-wire 4-wire Unitronics...
  • Page 13 ▪ Outputs O8 and O9 can independently be configured as either normal digital outputs or as high speed PWM outputs. ▪ Outputs O8 and O9 share the common point CM4. Normal Transistor Output High Speed PWM Output Unitronics...
  • Page 14 1. Disconnect the power supply. 2. Remove all wiring and disconnect any installed devices according to the device’s installation guide. 3. Unscrew and remove the mounting brackets, taking care to support the device to prevent it from falling during this procedure. Unitronics...
  • Page 15 Built-in series are PLC+HMI All-in-One programmable controllers that comprise built-in HMI and built-in I/Os. UniStream connects directly to UniCloud, Unitronics' IIoT cloud platform using built-in UniCloud connectivity. More information about UniCloud is available at www.unitronics.cloud. Model numbers in this document...
  • Page 16 Remote I/O Up to 8 UniStream Remote I/O Adapters (URB) Communication ports Built-in COM Specifications are provided below in the section Communications ports Add-on Ports Add up to 3 ports to a single controller using Uni-COM™ UAC-CX Modules Unitronics...
  • Page 17 Shielded CAT5e cable, up to 100 m (328 ft) USB device Number of ports Port type Mini-B Data rate USB 2.0 (480Mbps) Isolation None Cable USB 2.0 compliant; < 3 m (9.84 ft) USB host Number of ports Port type Type A Data rate USB 2.0 (480Mbps) Unitronics...
  • Page 18 10Hz, 50Hz, 60Hz, 400Hz Step response Smoothing Noise Rejection Frequency (0 to 100% of final 400Hz 60Hz 50Hz 10Hz value) None 2.7ms 16.86ms 20.2ms 100.2ms Weak 10.2ms 66.86ms 80.2ms 400.2ms Medium 20.2ms 133.53ms 160.2ms 800.2ms Strong 40.2ms 266.86ms 320.2ms 1600.2ms Unitronics...
  • Page 19 Number of outputs 2 (O8 and O9) Output type Transistor, Sink Isolation Output to bus 1,500VAC for 1 minute Output to output None Current 50mA max. per output Voltage Nominal: 24VDC Range: 3.5V to 28.8VDC On state voltage 1V max drop Unitronics...
  • Page 20 Nominal operating 24VDC voltage Operating voltage 20.4 – 28.8VDC Maximum current 30mA@24VDC consumption Current consumption does not include load current Environmental Protection Front face : IP66, NEMA 4X Rear side: IP20, NEMA1 Operating -20°C to 55°C (-4°F to 131°F) temperature Unitronics...
  • Page 21 Refer to the images on page 8 US7-xx-TR22 0.68 Kg (1.5 lb) US7-xx-T24 0.68 Kg (1.5 lb) US10-xx-B1 1.02 Kg (2.25 lb) Refer to the images on page 8 US10-xx-TR22 1.08 Kg (2.38 lb) US10-xx-T24 1.08 Kg (2.38 lb) UniStream 5” Unitronics...
  • Page 22 User Guide UniStream 7" UniStream 10.1" Unitronics...
  • Page 23 The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (1989) (R"G) Ltd. or other third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them.