Summary of Contents for Supermicro MicroBlade MBI-310T-4C2

  • Page 1 MicroBlade Server MBI-310T-4C2 MBI-310T-4T2N USER’S MANUAL Revision 1.0a...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Secure Data Deletion A secure data deletion tool designed to fully erase all data from storage devices can be found on our website: https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wdl/utility/...
  • Page 4: Table Of Contents

    Contents Contents Chapter 1 Introduction 1.1 Overview ..........................8 Eligible Enclosures ......................8 1.2 System Features ........................9 Front View ...........................9 Control Panel .........................10 Top view ..........................11 System Block Diagrams ....................13 1.3 Motherboard Layout ......................14 Quick Reference .......................15 Motherboard Block Diagram .....................16 Chapter 2 Installation and Setup 2.1 Unpacking the System .......................17 2.2 Installing or Removing the Blade Unit ................18 Installing a Blade Unit into the Enclosure .................18...
  • Page 5 Contents 3.2 Jumpers ..........................33 Explanation of Jumpers.....................33 3.3 LED Indicators ........................34 Chapter 4 Software 4.1 Microsoft Windows OS Installation ..................35 4.2 Driver Installation ........................37 4.3 SuperDoctor 5 ........................38 ® 4.4 BMC ............................39 BMC ADMIN User Password ...................39 Chapter 5 Optional Components 5.1 TPM Security Module ......................40 Chapter 6 Troubleshooting and Support 6.1 Information Resources ......................41...
  • Page 6 6.10 Reporting an Issue ......................54 Technical Support Procedures ..................54 Returning Merchandise for Service ...................54 Vendor Support Filing System ..................55 6.11 Feedback ...........................55 6.12 Contacting Supermicro ......................56 Appendix A BIOS POST Codes Appendix B Standardized Warning Statements for AC Systems Appendix C Specifications and Compliance...
  • Page 7 San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) Sales-USA@supermicro.com (Sales Inquiries) Government_Sales-USA@supermicro.com (Gov. Sales Inquiries) support@supermicro.com (Technical Support) RMA@supermicro.com (RMA Support) Webmaster@supermicro.com (Webmaster) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 8: Chapter 1 Introduction

    Chapter 1: Introduction Chapter 1 Introduction 1.1 Overview The MBI-310T-(4C2/4T2N) blade is a compact self-contained server that connects into a pre-cabled enclosure that provides power, cooling, management and networking functions. One enclosure can hold up to fourteen blades. Each blade contains one computing node. In this manual, “blade”...
  • Page 9: System Features

    Chapter 1: Introduction 1.2 System Features The following views of the system display the main features. Refer to Appendix C for additional specifications. Front View Service Tag Control Panel Latch Lever Figure 1-1. Front View Chassis Front Features Features Descriptons Control Panel Power button and status indicators Latch Lever...
  • Page 10: Control Panel

    Chapter 1: Introduction Control Panel Power System Fail LED NIC LED KVM/UID LED Power LED Figure 1-2. Control Panel Control Panel Features Feature State Description The main power switch applies or removes primary power from the power Power button supply to the server but maintains standby power. Green Power on Power LED...
  • Page 11: Top View

    Chapter 1: Introduction Top view BMC Password Sticker DIMM Slots CPU and Heatsink SATADOM M.2 Slot M.2 Slot Add-on Module Storage Drive Storage Drive Service/Asset Tag Latch Lever Figure 1-3. Components Labeled (MBI-310T-4T2N model shown)
  • Page 12 Chapter 1: Introduction Feature Description Drives Two 2.5" storage drives Slot for M.2 SSD memory card SATADOM SATA port that supports disk-on-module (DOM) Memory DIMM slots Processors and heatsinks Service/Asset Tag Pull-out identifier (with BMC ADMIN default password sticker) Latch Levers Levers for two latches that secure the blade in the enclosure CPU and Heatsink DIMM Slots...
  • Page 13: System Block Diagrams

    Chapter 1: Introduction System Block Diagrams MBI-310T-4T2N MBI-310T-4C2 Figure 1-5. System Block Diagrams...
  • Page 14: Motherboard Layout

    Chapter 1: Introduction 1.3 Motherboard Layout Below is a layout of the B3STI-CPU-001 motherboard with jumper, connector and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information and jumper settings, refer to Chapter 3 or the Motherboard Manual.
  • Page 15: Quick Reference

    Chapter 1: Introduction Quick Reference Jumper Description Default Setting JBR1 BIOS Recovery Pins 1-2 (Normal) JBT1 CMOS Clear Open (Normal) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPME1 ME Recovery Pins 1-2 (Normal) JPME2 ME Manufacturing Mode Pins 1-2 (Normal) JPT1 Onboard TPM 2.0 Enable/Disable Pins 2-3 (Disabled) JWD1...
  • Page 16: Motherboard Block Diagram

    Chapter 1: Introduction Motherboard Block Diagram SAS3 SVID 12Gb/s IMVP8 IMVP8 PCIe 3.0x8 LSI3008 DDR4 (CHA) DIMMA0 SAS3 8.0GT/s Intel 12Gb/s DIMMA1 PCIe 3.0x4 I350 LGA1200 8.0GT/s DDR4 (CHB) DIMMB0 PCIe 3.0x4 DIMMB1 8.0GT/s I350 x8 DMI PCIe 4.0 2x4 SlimSAS CONN 8GT/s 16GT/s...
  • Page 17: Chapter 2 Installation And Setup

    Chapter 2: Installation and Setup Chapter 2 Installation and Setup This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications or part numbers. Up to ten blade modules may be installed into a blade enclosure, depending upon your enclosure and blade.
  • Page 18: Installing Or Removing The Blade Unit

    Chapter 2: Installation and Setup 2.2 Installing or Removing the Blade Unit Installing a Blade Unit into the Enclosure 1. Pull the locking lever out, and push the blade into its bay. Caution: Insert the blade carefully so the rear connectors are not damaged. 2.
  • Page 19: Powering Up Or Down

    • Thermal grease is pre-applied on new heatsinks. No additional thermal grease is needed. • Refer to the Supermicro website for updates on processor support. • Graphics in this manual are for illustration only. Your components may look different.
  • Page 20: Installing The Lga1200 Processor

    Chapter 2: Installation and Setup Installing the LGA1200 Processor 1. Press the load lever down to release the load plate from its locking position. Plastic Protective Load Plate Cover Load Lever 2. Gently lift the load lever to open the load plate. Remove the plastic protective cover. Do not touch the CPU socket contacts.
  • Page 21 Chapter 2: Installation and Setup 3. Locate the triangle on the CPU and CPU socket, which indicates the location of Pin 1. Holding the CPU by the edges with your thumb and index finger, align the triangle on the CPU with the triangle on the socket. The CPU keys (the semi-circle cutouts) may also be aligned against the socket keys as a guide.
  • Page 22: Installing The Cpu Heatsink

    Chapter 2: Installation and Setup Installing the CPU Heatsink 1. Do not apply thermal grease to the heatsink or the CPU; the required amount has already been applied. 2. Align the four holes of the heatsink with the four mounting holes on the motherboard. 3.
  • Page 23: Removing The Heatsink

    Chapter 2: Installation and Setup Removing the Heatsink Note: We do not recommend that the CPU or heatsink be removed. However, if you do need to remove the heatsink, please follow the instructions below to remove the heatsink and prevent damage done to the CPU or other components. 1.
  • Page 24: Memory

    Installing an odd-numbered modules (one or three) is supported, but for best memory performance, a balanced memory population is recommended. Memory Population Guidelines The following memory population table was created based on guidelines provided by Intel to support Supermicro motherboards. Memory Slots DIMMA1 DIMMB1...
  • Page 25 Chapter 2: Installation and Setup JPG1 JWD1 SRW1 SRW2 JBT1 JSD1 JTPM1 DIMMA1 DIMMA2 DIMMB1 DIMMB2 B3ST1-CPU-001 REV:1.00 Figure 2-2. Memory Slots Labeled...
  • Page 26: Installing Memory

    Chapter 2: Installation and Setup Installing Memory ESD Precautions Electrostatic Discharge (ESD) can damage electronic com ponents including memory modules. To avoid damaging DIMM modules, it is important to handle them carefully. The following measures are generally sufficient. • Use a grounded wrist strap designed to prevent static discharge. •...
  • Page 27: Storage Drives

    Chapter 2: Installation and Setup 2.6 Storage Drives The blade has two 2.5" internal storage drive bays. Note: Enterprise level storage drives are recommended for use in Supermicro systems. For information on recommended drives, visit the Supermicro website. Installing a Drive 1.
  • Page 28: Checking The Temperature Of An Nvme Drive

    Chapter 2: Installation and Setup Checking the Temperature of an NVMe Drive There are two ways to check using the BMC Dashboard. Checking a Drive • BMC Dashboard > Server Health > NVMe SSD – Shows the temperatures of all NVMe drives.
  • Page 29: System Cooling

    Chapter 2: Installation and Setup 2.7 System Cooling Installing the Air Shrouds Air shrouds concentrate airflow to maximize fan efficiency. Screw Path of Air Shroud Figure 2-4. Installing the Air Shroud 1. Bend the air shroud along the path shown above, between the DIMMs and the CPU heatsink and curving to the edge of the motherboard.
  • Page 30: Checking The Server Air Flow

    Chapter 2: Installation and Setup Checking the Server Air Flow • Make sure there are no objects to obstruct airflow in and out of the server. • Do not operate the server without drive carriers in the drive bays. • Use only recommended server parts.
  • Page 31: Chapter 3 Motherboard Connections

    The JTPM1 header is used to connect a Trusted Platform Module (TPM)/Port 80, which is available from Supermicro. A TPM/Port 80 connector is a security device that supports encryption and authentication in hard drives. It allows the motherboard to deny access if the TPM associated with the storage drive is not installed in the system.
  • Page 32 SATA 3.0 with DOM power receptacle connector and one SATA 3.0 right angle receptacle connector. Supermicro SuperDOMs are backward compatible with regular SATA HDDs or SATA DOMs that need external power cables. Set J3 to pins 1-2 to use the SATA port as onboard SATA or pins 2-3 as AOC SAS.
  • Page 33: Jumpers

    Chapter 3: Motherboard Connections 3.2 Jumpers Explanation of Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional settings. Jumpers create shorts between two pins to change the function associated with it. Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard layout page for jumper locations.
  • Page 34: Led Indicators

    Chapter 3: Motherboard Connections VGA Enable/Disable Use jumper JPG1 to enable or disable the VGA port using the onboard graphics controller. VGA Enable/Disable Jumper Settings Jumper Setting Definition Pins 1-2 Enabled (Default) Pins 2-3 Disabled ME Recovery JPME1 is used for ME Firmware Recovery mode, which will limit system resource for essential function use only without putting restrictions on power use.
  • Page 35: Chapter 4 Software

    USB/SATA DVD drive, or a USB flash drive, or the BMC KVM console. 2. Retrieve the proper RST/RSTe driver. Go to the Supermicro web page for your motherboard and click on "Download the Latest Drivers and Utilities", select the proper driver, and copy it to a USB flash drive.
  • Page 36 Chapter 4: Software 4. During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on “Load driver” link at the bottom left corner. Figure 4-2.
  • Page 37: Driver Installation

    The Supermicro website contains drivers and utilities for your system at https://www. supermicro.com/wdl/driver. Some of these must be installed, such as the chipset driver. After accessing the website, go into the CDR_Images (in the parent directory of the above link) and locate the ISO file for your motherboard. Download this file to to a USB flash drive or a DVD.
  • Page 38: Superdoctor ® 5

    4.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 39: Bmc

    This can be found on a sticker on the chassis and a sticker on the motherboard. The sticker also displays the BMC MAC address. If necessary, the password can be reset using the Supermicro IPMICFG tool. Figure 4-5. BMC Password Label The sticker can be found on the pull-out service tag at the front of the chassis.
  • Page 40: Chapter 5 Optional Components

    The JTPM1 header is used to connect a Trusted Platform Module (TPM). A TPM is a security device that supports encryption and authentication in hard drives. It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system. Details and installation procedures are at: http://www.supermicro.com/manuals/other/TPM.pdf.
  • Page 41: Chapter 6 Troubleshooting And Support

    Chapter 6 Troubleshooting and Support 6.1 Information Resources Website A great deal of information is available on the Supermicro website, supermicro.com. Menu Icon' Figure 6-1. Supermicro Website Click the menu icon, the three bars in the upper right corner, then select: •...
  • Page 42: Bmc Interface

    Security Center for recent security notices Supermicro Phone and Addresses 6.2 BMC Interface The system supports a Baseboard Management Controller (BMC) interface. It provides remote access, monitoring and management. There are several BIOS settings related to the BMC.
  • Page 43: Troubleshooting Procedures

    Chapter 6: Troubleshooting and Support 6.3 Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the Technical Support Procedures Returning Merchandise for Service sections in this chapter. Power down the system before changing any non hot-swap hardware components.
  • Page 44: Losing The System Setup Configuration

    Also check the Control panel Overheat LED. • Adequate power supply: Make sure that the power supply provides adequate power to the system. Make sure that all power connectors are connected. Refer to the Supermicro website for the minimum power requirements. •...
  • Page 45 Chapter 6: Troubleshooting and Support • Use the minimum configuration for troubleshooting: Remove all unnecessary components (starting with add-on cards first), and use the minimum configuration (but with a CPU and a memory module installed) to identify the trouble areas. •...
  • Page 46: Replacing The Battery

    Chapter 6: Troubleshooting and Support 6.4 Replacing the Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery Begin by removing power from the system.
  • Page 47: Crash Dump Using The Bmc Dashboard

    In the event of a processor internal error (IERR) that crashes your system, you may want to provide information to support staff. You can download a crash dump of status information using the BMC Dashboard. The BMC manual is available at www.supermicro.com/manuals/ other/BMC_Users_Guide_X12_H12.pdf. Check Error Log 1.
  • Page 48: Uefi Bios Recovery

    Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
  • Page 49 USB device or a writable CD/DVD. Note 1: If you cannot locate the "Super.ROM" file in your drive disk, visit our website at www.supermicro.com to download the BIOS package. Extract the BIOS binary image into a USB flash device and rename it "Super.ROM" for the BIOS recovery use.
  • Page 50 Chapter 6: Troubleshooting and Support Note: At this point, you may decide if you want to start the BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below. 4. When the screen as shown above displays, use the arrow keys to select the item "Proceed with flash update"...
  • Page 51 Chapter 6: Troubleshooting and Support 7. Press <Del> continuously during system boot to enter the BIOS Setup utility. From the top of the tool bar, select Boot to enter the submenu. From the submenu list, select Boot Option #1 as shown below. Then, set Boot Option #1 to [UEFI AP:UEFI: Built-in EFI Shell]. Press <F4>...
  • Page 52 Chapter 6: Troubleshooting and Support Note: Do not interrupt this process until the BIOS flashing is complete. 9. The screen above indicates that the BIOS update process is complete. When you see the screen above, unplug the AC power cable from the power supply, clear CMOS, and plug the AC power cable in the power supply again to power on the system.
  • Page 53: Cmos Clear

    Chapter 6: Troubleshooting and Support 6.7 CMOS Clear JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS. To Clear CMOS 1.
  • Page 54: Where To Get Replacement Components

    6.9 Where to Get Replacement Components If you need replacement parts for your system, to ensure the highest level of professional service and technical support, purchase exclusively from our Supermicro Authorized Distributors/System Integrators/Resellers. A list can be found at: http://www.supermicro.com.
  • Page 55: Vendor Support Filing System

    For issues related to Red Hat Enterprise Linux, since it is a subscription based OS, contact your account representative. 6.11 Feedback Supermicro values your feedback as we strive to improve our customer experience in all facets of our business. To provide feedback on our manuals, please email us at techwriterteam@...
  • Page 56: Contacting Supermicro

    San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) Sales-USA@supermicro.com (Sales Inquiries) Government_Sales-USA@supermicro.com (Gov. Sales Inquiries) support@supermicro.com (Technical Support) RMA@supermicro.com (RMA Support) Webmaster@supermicro.com (Webmaster) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 57: Appendix A Bios Post Codes

    Appendix A: BIOS POST Codes Appendix A BIOS POST Codes A.1 BIOS POST Messages During the Power-On Self-Test (POST), the BIOS will check for problems. If a problem is found, the BIOS will activate an alarm or display a message. The following is a list of such BIOS messages.
  • Page 58 Appendix A: BIOS POST Codes BIOS POST Messages BIOS Message Description Previous POST did not complete successfully. POST loads default values and offers to run Setup. If the failure was caused by incorrect values and Previous boot incomplete - they are not corrected, the next boot will likely fail. On systems with control of Default configuration used wait states, improper Setup settings can also terminate POST and cause this error on the next boot.
  • Page 59 Appendix A: BIOS POST Codes BIOS POST Messages BIOS Message Description nnnn kB Extended RAM Where nnnn is the amount of RAM in kilobytes successfully tested. Passed nnnn Cache SRAM Passed Where nnnn is the amount of system cache in kilobytes successfully tested. nnnn kB Shadow RAM Passed Where nnnn is the amount of shadow RAM in kilobytes successfully tested.
  • Page 60 Appendix A: BIOS POST Codes One long and two short beeps – video configuration error One repetitive long beep – no memory detected Terminal POST Errors If a terminal type of error occurs, BIOS will shut down the system. Before doing so, BIOS will write the error to port 80h, attempt to initialize video and write the error in the top left corner of the screen.
  • Page 61 Appendix A: BIOS POST Codes Terminal POST Errors Code Description 1-3-1-1 Test DRAM refresh 1-3-1-3 Test 8742 Keyboard Controller Auto size DRAM Initialize POST Memory Manager Clear 512 kB base RAM 1-3-4-1 RAM failure on address line xxxx* 1-3-4-3 RAM failure on data bits xxxx* of low byte of memory bus Enable cache before system BIOS shadow Test CPU bus-clock frequency Initialize Phoenix Dispatch Manager...
  • Page 62 Appendix A: BIOS POST Codes Terminal POST Errors Code Description Test keyboard Set key click if enabled Enable USB devices 2-2-3-1 Test for unexpected interrupts Initialize POST display service Display prompt “Press F2 to enter SETUP” Disable CPU cache Test RAM between 512 and 640 kB Test extended memory Test extended memory address lines Jump to UserPatch1...
  • Page 63 Appendix A: BIOS POST Codes Terminal POST Errors Code Description Detect and install external parallel ports Initialize PC-compatible PnP ISA devices Re-initialize onboard I/O ports. Configure Motherboard Configurable Devices (optional) Initialize BIOS Data Area Enable Non-Maskable Interrupts (NMIs) Initialize Extended BIOS Data Area Test and initialize PS/2 mouse Initialize floppy controller Determine number of ATA drives (optional)
  • Page 64 Appendix A: BIOS POST Codes Terminal POST Errors Code Description Clear Boot flag Check for errors Inform RomPilot about the end of POST. POST done - prepare to boot operating system 1 One short beep before boot Terminate QuietBoot (optional) Check password (optional) Initialize ACPI BIOS Prepare Boot...
  • Page 65 Appendix A: BIOS POST Codes Terminal POST Errors Code Description Initialize digitizer and display message Unknown interrupt The following are for the boot block in Flash ROM: Boot Block Flash ROM Terminal POST Errors Code Description Initialize the chipset Initialize the bridge Initialize the CPU Initialize system timer Initialize system I/O...
  • Page 66 Appendix A: BIOS POST Codes Boot Block Flash ROM Terminal POST Errors Code Description Initialize interrupt vectors Initialize Run Time Clock Initialize video Initialize System Management Manager Output one beep Clear Huge Segment Boot to Mini DOS Boot to Full DOS If the BIOS detects error 2C, 2E, or 30 (base 512K RAM error), it displays an additional word- bitmap (xxxx) indicating the address line or bits that failed.
  • Page 67: Appendix B Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
  • Page 68 Appendix B: Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 69 Appendix B: Warning Statements . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬ ٍ...
  • Page 70 Appendix B: Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 71 Appendix B: Warning Statements Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 72 Appendix B: Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために、...
  • Page 73 Appendix B: Warning Statements ‫אזהרה מפני ניתוק חשמלי‬ ‫!אזהרה‬ ‫יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק‬ ‫.לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים‬ ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬ ‫انطاقت...
  • Page 74 Appendix B: Warning Statements ¡Advertencia! Solamente el personal calificado debe instalar, reemplazar o utilizar este equipo. Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד‬ ‫واملدربيه...
  • Page 75 Appendix B: Warning Statements Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
  • Page 76 Appendix B: Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
  • Page 77 Appendix B: Warning Statements ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일하거나 제 조사에서...
  • Page 78 Appendix B: Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
  • Page 79 Appendix B: Warning Statements Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
  • Page 80 Appendix B: Warning Statements ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
  • Page 81 Appendix B: Warning Statements ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
  • Page 82 Appendix B: Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص...
  • Page 83 Appendix B: Warning Statements Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
  • Page 84 Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
  • Page 85 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro.
  • Page 86 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
  • Page 87: Appendix C Specifications And Compliance

    Appendix C Specifications and Compliance Appendix C Specifications and Compliance Processors Intel Xeon E-2300 family processor in Socket H5 (LGA 1200) Chipset Intel C256 Memory Up to 128GB of ECC and Non-ECC UDIMM DDR4 memory with speeds of up to 3200MHz in four memory slots BIOS A256Mb AMI BIOS SPI Flash BIOS...
  • Page 88 Appendix C Specifications and Compliance Regulatory Compliance FCC, ICES, CE, VCCI, RCM, UKCA, NRTL, CB Applied Directives, Standards EMC/EMI: 2014/30/EU (EMC Directive) Electromagnetic Compatibility Regulations 2016 FCC Part 15 ICES-003 VCCI-CISPR 32 AS/NZS CISPR 32 BS/EN55032 BS/EN55035 CISPR 32 CISPR 35 BS/EN 61000-3-2 BS/EN 61000-3-3 BS/EN 61000-4-2...