3. Inspection and Adjustement
l
Measurement
with hydrometer
When using a hydrometer,
the measured
specific gravity must be corrected accord-
ing to the temperature
at the time of mea-
surement.
The specific
gravity of battery
electrolyte
is defined
with 20°C as the
standard.
Since the specific
gravity
in-
creases or decreases by 0.0007 when the
temperature
varies
by l"C,
correct
the
value according to the equation below.
D = St + 0.007 (t - 20)
L
1 Electrolyte tempera-
ture at measurement
Specific
gravity
at mea-
surement
L
-Converted
specific gravity at 20%
Specific
gravity
and remaining
battery
charge
I
Specific
1 Discharged
1 Remaining1
1.210
25
75
1.160
50
50
1.110
75
25
1.060
100
0
Terminals
Clean if corroded or soiled.
Mounting
bracket
Repair or replace it if corroded.
Retighten if loosened.
Battery appearance
Replace
the battery
if cracked
or de-
formed.
Clean with fresh water if contaminated.
Battery charge meas
with
a hvdrometer
Rubber bulb
Glass tube
Hvdrometer structure
How to read hydrometer