8. Turbocharger
(for 4TNE106T)
(3.1) Method for checking the waste gate valve opening pressure and lift
@
Equipment
Prepare the equipment
shown in the figure below.
@
Measuring
instruments
and devices
Dial gage
Capable of measuring 0 to 10 mm (A flat head type is recommendable.)
Manometer
Mercury column or electrical type (capable of measuring 0 to 1500 mmHg)
Pressure regulating valve
Allowing gradual adjustment in a range between 0 and 2 kgf/cm2 (0.196 Mpa)
Pressure reducing valve
Used for suppressing the air supply pressure at 5 kgf /cm* (0.49 Mpa) or less.
1 Pressure gage
1 Bourdon tube pressure gage (0 to 10 kgf/cm* (0.98 Mpa))
I
Waste gate actuator
0
a.
b.
C.
0
.
.
.
.
.
.
.
\
Waste gate valve
pre,?;.
redz;;vegulating
valve
Manometer
[Note] PC (controller pressure) varies with the set
output in a range between 600 and 750 mmHg.
Check method
Set the manometer
control pressure (PC) applied to the waste gate actuator to 0 and set
the dial gage to the zero point.
Gradually open the pressure regulating valve and measure the PC value when the actua-
tor rod is operated by 2 mm.
For the hysteresis,
let the rod move to 3 mm first.
The gradually
close the pressure
regulating
valve, measure the pressure when the rod is moved to 2 mm and obtain the
difference from the pressure measured in b. above.
Precautions
Set the dial gage on the extension
line of the actuator rod.
The piping and joints shall completely
be free from leak.
Fix the turbocharger
and dial gage securely.
If an electric manometer
is used, it shall have sufficient
precision.
Even when an electric manometer
is used, use of a mercury column type manometer
in
combination
is recommended
for calibration
and daily check.
The speed for increasing/decreasing
PC by means of the pressure regulating
valve shall
be very slow near the measuring point. If the 2 mm position is exceeded,
restart from the
beginning.
Do not apply over 5 kgf/cm2 (0.49 MPa) to the actuator.
(3.2) Waste gate actuator leak test
Apply 1.2 kgf/cm2 (0.12 Mpa) to the actuator and hold the state for 1 minute.
The actuator is
good if the pressure then is 1 .l kgf/cm2 (0.11 MPa) or above.
a-7